Output ratings and duty
The 3AXD50000047697: Normal-use output is 7.5 kW / 17.0 A; heavy-duty drops to 5.5 kW / 12.6 A. Light-overload use is listed at 7.5 kW / 16.2 A — essentially the same power as normal use but with slightly lower current headroom. Apparent power output is 12 kV·A. UL ratings: 10 Hp normal-use, 14.0 A; 7.5 Hp heavy-duty, 12 A.
I/O and environment
Two analog inputs, two analog outputs. Six digital inputs, three digital outputs. No industrial Ethernet interface on this variant — BACnet is the onboard protocol. Ambient temperature max 50 °C, altitude 4000 m. Standby loss 36 W, power consumption at rated output 436 W. Sound level 57 dB(A). Enclosure NEMA Type 1. Includes control unit. The internal lithium coin cell (CR2032, 220 mAh) backs the real-time clock.