Skip to main content
ABB 3AXD50000050474 — AC Drive (VFD) 480V

ABB 3AXD50000050474 ACH580-07 Cabinet Drive, 450 kW

MPN3AXD50000050474
Active

ABB ACH580-07 LV AC cabinet-built drive, 3AXD50000050474, 450 kW / 820 A normal duty, 355 kW / 625 A heavy duty, 380-480 V, IP21, Type 1, frame R11.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3AXD50000050474 — Power & Output
ParameterValue
Output power, normal duty450 kW
Output current, normal duty820 A
Output power, heavy duty355 kW
Output current, heavy duty625 A
Output power, light overload450 kW
Output current, light overload810 A
Output current, light overload (UL rating)807 A
Apparent power output568 kV·A
Output power, light overload (UL rating, Hp)700 Hp
3AXD50000050474 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000050474 — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeCabinet-built
3AXD50000050474 — Environmental
ParameterValue
Temperature rating (max.)Maximum 40 °C
3AXD50000050474 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)500 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)625 A

Product details

The ABB 3AXD50000050474 is the order code for a cabinet-built LV AC drive, frame size R11, rated 450 kW normal-duty output at 820 A and 355 kW heavy-duty at 625 A on a 400 V supply. It ships with the control unit included and is configured for 3-phase input at 380...480 V, 47.5...63 Hz. The IP21 / NEMA Type 1 enclosure suits indoor installation in HVAC plant rooms or light industrial environments. Normal-duty current of 820 A covers centrifugal pumps and fans with constant torque profiles. The UL listing shows 500 Hp heavy-duty and 700 Hp light-overload, so the drive is dual-rated for North American and IEC specs.

Integration notes

The drive includes 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs. BACnet is the listed communication protocol, which aligns with HVAC building management integration. No industrial Ethernet interface is onboard — BACnet MS/TP over RS-485 is the primary fieldbus. The control unit is included in the delivery; no separate ordering needed. Cabinet-built means the drive arrives as a self-contained assembly with power section, control, and auxiliaries wired. The R11 frame is large — expect a floor-standing cabinet, not a wall-mount. Sound level is rated at 72 dB(A), so plan for acoustic isolation if installed near occupied spaces. Ambient temperature limit is 40 °C maximum; derate above that. Operating humidity range is 5 to 95% non-condensing.

Compliance documentation

The drive carries a lithium coin cell (CR2032, 220 mAh, 3 V) for real-time clock backup. WEEE category 4 (Large Equipment) applies for end-of-life take-back. Ecodesign energy efficiency data is not provided because cabinet-built drives with conform modules are excluded from EU 2019/1781 scope per §2.3.e.

Frequently asked questions

What is the SCIP number for this drive?

The SCIP number is 2361a3f3-2fee-41b4-bbdb-00925564e194 Finland.

Does the drive include the control unit?

Yes, the control unit is included with the order code 3AXD50000050474.

What are the key ratings for normal and heavy duty?

Normal-duty output is 450 kW / 820 A; heavy-duty output is 355 kW / 625 A. Light-overload output is 450 kW / 810 A. UL ratings are 700 Hp / 807 A light-overload and 500 Hp / 625 A heavy-duty.

MPN
3AXD50000050474