Duty ratings and environment
The 3AXD50000108398: Normal-use output is 2.2 kW at 9.8 A. Heavy-duty use drops to 1.5 kW at 7.8 A, and light-overload use holds at 2.2 kW but at 9.3 A. UL heavy-duty output is 2 Hp at 7.5 A, light-overload UL output is 2 Hp at 9.3 A. The efficiency level is IE2. Standby loss is 15 W, power consumption at rated load is 140 W, and apparent power output is 3.9 kV·A. Power factor is 0.98. Enclosure is Open Type per NEMA, with IP20 degree of protection. Sound level is 63.10 dB(A).
Digital I/O: 2 inputs, 1 output. No analog I/O. No industrial Ethernet interface. Communication is via CAN. Mounting is module-style, frame R1.