Output ratings and duty selection
The 3AXD50000136797: Three duty ratings are specified: normal use (Pn 1.5 kW, In 7.8 A), heavy-duty use (PhD 1.1 kW, IhD 6.9 A), and light-overload use (PlD 1.5 kW, IlD 7.5 A). The heavy-duty figure governs continuous operation under high starting torque or cyclic loads; the normal and light-overload figures are for lower-duty profiles. UL listings match: heavy-duty 1.5 Hp / 6.6 A, light-overload 2 Hp / 7.5 A.
Supply and environmental limits
Input is 200–240 V three-phase, 47.5–63 Hz. Ambient temperature maximum 50 °C, operating humidity 5–95 % RH non-condensing, altitude up to 1000 m without derating. Enclosure is IP20 open type (NEMA Open Type). Standby loss is 15 W; full-load power consumption is 105 W. Apparent power output is 3.1 kV·A. Sound level 63.1 dB(A).
Digital I/O: 2 inputs, 1 output. No analog I/O. Communication is via CAN; no industrial Ethernet interface on this module.