Skip to main content
ABB 3AXD50000145874 — AC Drive (VFD) 600V

ABB 3AXD50000145874 ACS880-17 Drive, 315 kW, 320 A

MPN3AXD50000145874
Active

ABB ACS880-17 regenerative drive, 3AXD50000145874, 315 kW / 320 A normal use, 525-690 V input, IP22, R8i frame, active.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000145874 — Identification
ParameterValue
Frame sizeR8i+R8i
3AXD50000145874 — Electrical (input)
ParameterValue
Input voltage range525 ... 690 V
Number of phases3-phase
Frequency range48 ... 63 Hz
3AXD50000145874 — Output / Performance
ParameterValue
Output power, normal duty315 kW
Output power, heavy duty200 kW
Output power, light overload250 kW
Output current, normal duty320 A
Output current, heavy duty239 A
Output current, light overload307 A
Output power (UL), light overload300 Hp
Output power (UL), heavy duty250 Hp
Output current (UL), light overload307 A
Output current (UL), heavy duty239 A
3AXD50000145874 — Mechanical
ParameterValue
NEMA enclosure typeType1
3AXD50000145874 — Environmental
ParameterValue
Degree of protection (IEC, IP)IP22

Product details

The ABB 3AXD50000145874 is an ACS880-17-0320A-7 regenerative drive rated 315 kW normal-use output power at 320 A, with a heavy-duty rating of 200 kW / 239 A and a light-overload rating of 250 kW / 307 A. Input voltage is 525 to 690 V three-phase, 48 to 63 Hz. The R8i+R8i frame includes the control unit and carries an IP22 enclosure (NEMA Type 1).

Duty-cycle selection — normal, heavy, or light overload

Three duty ratings let you match the drive to the load profile. Normal use (315 kW / 320 A) covers constant-torque applications. Heavy-duty (200 kW / 239 A) handles higher peak demands — crushers, conveyors, extruders. Light-overload (250 kW / 307 A) suits variable-torque loads like pumps and fans where occasional overload is acceptable. The UL listing mirrors these: 350 Hp normal, 250 Hp heavy-duty, 300 Hp light-overload.

The drive includes 4 analog inputs, 4 analog outputs, 14 digital inputs, and 10 digital outputs. Communication is via CAN; no onboard Industrial Ethernet. Ambient operating temperature is maximum 40 °C, with humidity range 5 to 95% RH. Altitude rating is 1000 m. Sound level is 75 dB(A).

Frequently asked questions

What is the SCIP number for this drive?

SCIP 944D8A5E-036D-404E-9036-0D3C1EA703AD, registered in Finland.

What are the normal-use power and current ratings?

315 kW output power at 320 A, with a UL equivalent of 350 Hp at 320 A.

What input voltage does this drive accept?

525 to 690 V three-phase, 48 to 63 Hz.

MPN
3AXD50000145874