The 3AXD50000146154: Heavy-duty use drops to 160 kW / 174 A; light-overload use holds at 200 kW / 200 A. UL listing shows 175 Hp heavy-duty and 200 Hp light-overload. The 251 kV·A apparent power output gives headroom for motor starting and transient loads.
Environment and compliance
Maximum ambient 40 °C, altitude 1000 m, humidity 5-95% non-condensing. Sound level 77 dB(A). SCIP number 9ECED1FE-316A-4BF4-991E-2606BB5FE13A Finland on file. Exempt from EU ecodesign efficiency reporting per Regulation EU/2019/1781 §2.3.d — low-harmonic topology is the reason.
I/O and interfaces
Two analog inputs, two analog outputs. Seven digital inputs, five digital outputs. CAN protocol onboard; no industrial Ethernet interface. Control unit included. Lithium coin cells (CR2032, 2 pcs) for real-time clock backup.