Skip to main content
ABB 3AXD50000158973 — AC Drive (VFD) 600V

ABB 3AXD50000158973 ACS880-04F Drive Module, 560 kW, 590 A

MPN3AXD50000158973
Active

ABB ACS880-04F-590A-7, LV AC industrial flange-mounted single drive module, IEC: Pn 560 kW, 590 A, 690 V, UL: Pld 600 Hp, 571 A, 575 V, frame size R11.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000158973 — Identification
ParameterValue
Frame sizeR11
3AXD50000158973 — Electrical (input)
ParameterValue
Input voltage range525 ... 690 V
Number of phases3-phase
Frequency range47.5 ... 63 Hz
3AXD50000158973 — Output / Performance
ParameterValue
Output power, normal duty560 kW
Output power, heavy duty500 kW
Output power, light overload560 kW
Output current, normal duty590 A
Output current, heavy duty505 A
Output current, light overload571 A
Efficiency level (IE class)IE2
Output power (UL), light overload600 Hp
Output power (UL), heavy duty500 Hp
Output current (UL), light overload571 A
Output current (UL), heavy duty505 A
3AXD50000158973 — Mechanical
ParameterValue
Mounting typeModule
NEMA enclosure typeOpen Type
3AXD50000158973 — Environmental
ParameterValue
Degree of protection (IEC, IP)IP20

Product details

The ABB 3AXD50000158973 is the ACS880-04F-590A-7, a flange-mounted single drive module for LV AC industrial applications. It delivers 560 kW (590 A) in normal use and 500 kW (505 A) in heavy-duty use, with a light-overload rating of 571 A. Input voltage range is 525 to 690 V three-phase at 47.5 to 63 Hz.

Ratings and duty cycles

Normal-use output is 560 kW at 590 A; heavy-duty use drops to 500 kW at 505 A. Light-overload use holds at 560 kW but current rises to 571 A. Apparent power output is 705 kV·A. The module is rated for a maximum ambient temperature of 40 °C and altitude up to 4000 m.

Power consumption and standby loss

Power consumption is 7130 W, with standby loss of 438 W. The module includes a control unit and mounts as an IP20 Open Type unit in frame size R11.

Onboard I/O includes 2 analog inputs, 2 analog outputs, and 6 digital inputs / 2 digital outputs. Communication is over CAN; no industrial Ethernet interface is fitted. A CR2032 lithium coin cell backs the real-time clock.

Frequently asked questions

What are the key output ratings for this drive module?

Normal-use output is 560 kW at 590 A; heavy-duty use is 500 kW at 505 A; light-overload use is 560 kW at 571 A. Apparent power output is 705 kV·A.

What compliance documentation is available for this module?

RoHS compliance dated 20240508, REACH declaration dated 20250905, and SCIP number e7d01a07-ae61-49b4-b4bb-74f563632932 Finland are on file. UL listings cover heavy-duty and light-overload use.

What is the input voltage and frequency range?

Input voltage is 525 to 690 V three-phase, frequency range 47.5 to 63 Hz.

What is the frame size and enclosure type?

Frame size is R11, enclosure is IP20 Open Type.

MPN