Electrical Output

3AXD50000162079 — Electrical Output
ParameterValue
Output power, normal duty (Pn)0.37 kW
Output current, normal duty (In)2.4 A
Output power, heavy duty (PhD)0.25 kW
Output current, heavy duty (IhD)1.8 A
Output power, light-overload duty (PlD)0.37 kW
Output current, light-overload duty (IlD)2.3 A
Output power, heavy duty (UL, Hp)0.33 Hp
Output current, heavy duty (UL)1.8 A
Apparent power output1.0 kV·A
Output power, light-overload duty (UL, Hp)0.5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)2.3 A
Standby loss14 W
Power consumption39 W

Electrical Input

3AXD50000162079 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98

Control & I/O

3AXD50000162079 — Control & I/O
ParameterValue
Digital inputs / outputs2 / 1
Communication protocolCAN
Analog inputs0
Analog outputs0
Hardware interfacesIndustrial Ethernet 0

Environmental

3AXD50000162079 — Environmental
ParameterValue
Temperature rating, max.Maximum 50 °C
Operating humidity5 ... 95
Altitude1000 m
Noise level63.10 dB(A)

Mechanical

3AXD50000162079 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR1
Mounting typeModule

Approvals

3AXD50000162079 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

The ABB 3AXD50000162079 is a drive control unit in the R1 frame size, rated for 200-240 V three-phase input. Normal-use output is 0.37 kW at 2.4 A; heavy-duty use drops to 0.25 kW at 1.8 A. Light-overload use holds at 0.37 kW with 2.3 A output. IE2 efficiency class, IP20 open-type enclosure, CAN communication interface.

Module mounting, R1 frame. Rated for maximum 50 °C ambient, 5-95% RH non-condensing, altitude 1000 m. Standby loss 14 W; power consumption 39 W at rated load. Sound level 63.1 dB(A). No battery included. WEEE category 5 (small equipment under 50 cm). 2 digital inputs, 1 digital output, no analog I/O, no industrial Ethernet interface.

Frequently asked questions

What are the key output ratings?

Normal-use: 0.37 kW at 2.4 A. Heavy-duty: 0.25 kW at 1.8 A. Light-overload: 0.37 kW at 2.3 A.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU (date 20230303). REACH declaration (date 20250905). UL ratings for heavy-duty and light-overload use. SCIP number 483516f7-5042-4d76-a918-d7fab20a54ce Finland.

What is the input voltage and phase?

200-240 V, three-phase, 47.5-63 Hz.

What is the SCIP number?

483516f7-5042-4d76-a918-d7fab20a54ce Finland.

MPN
3AXD50000162079