Rating breakdown
The 3AXD50000162093: Normal-use (Pn) output is 0.75 kW at 4.8 A; light-overload use (PlD) matches that at 4.6 A. Input frequency range is 47.5-63 Hz, so it handles weak-grid or generator supply without derating. Standby loss is 14 W; full-load power consumption is 72 W. Power factor at rated load is 0.98.
I/O and interfaces
Two digital inputs and one digital output — no analog I/O on this variant. CAN is the only hardware interface; no Ethernet port.