Skip to main content
ABB 3AXD50000162109 — AC Drive (VFD) 240V

ABB 3AXD50000162109 Drive Control Unit, R1 Frame, 1.1 kW

MPN3AXD50000162109
Active

ABB drive control unit, frame size R1, 1.1 kW normal-use output, 6.9 A, IP20, CAN interface.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000162109 — Electrical Output
ParameterValue
Output power, normal duty (Pn)1.1 kW
Output current, normal duty (In)6.9 A
Output power, heavy duty (PhD)0.75 kW
Output current, heavy duty (IhD)4.8 A
Output power, light-overload duty (PlD)1.1 kW
Output current, light-overload duty (IlD)6.6 A
Output power, heavy duty (UL, Hp)1 Hp
Output current, heavy duty (UL)4.6 A
Apparent power output2.7 kV·A
Output power, light-overload duty (UL, Hp)1.5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)6.6 A
Standby loss14 W
Power consumption111 W

Electrical Input

3AXD50000162109 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98

Control & I/O

3AXD50000162109 — Control & I/O
ParameterValue
Digital inputs / outputs2 / 1
Communication protocolCAN
Analog inputs0
Analog outputs0
Hardware interfacesIndustrial Ethernet 0

Environmental

3AXD50000162109 — Environmental
ParameterValue
Temperature rating, max.Maximum 50 °C
Operating humidity5 ... 95
Altitude1000 m
Noise level63.10 dB(A)

Mechanical

3AXD50000162109 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR1
Mounting typeModule

Approvals

3AXD50000162109 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

What this control unit delivers

The ABB 3AXD50000162109 is a drive control unit in frame size R1, rated for 1.1 kW normal-use output at 6.9 A. Heavy-duty use drops to 0.75 kW and 4.8 A, which is the rating to check if the motor runs a constant-torque load like a conveyor or positive-displacement pump. Light-overload use (typically variable-torque fans or pumps) stays at 1.1 kW / 6.6 A. Input voltage is 200–240 V three-phase, frequency 47.5–63 Hz, so it fits standard 208/230 VAC industrial supplies.

IP20 open-type enclosure, rated for a maximum 50 °C ambient and 1000 m altitude without derating. Sound level is 63.1 dB(A) — noticeable but not deafening in a small cabinet. Standby loss of 14 W and power consumption of 111 W at full load give a power factor of 0.98. Humidity range 5–95% non-condensing.

2 digital inputs and 1 digital output, no analog I/O. Communication is CAN — no onboard Ethernet. If the application needs Modbus TCP or PROFINET, this unit requires an external gateway or a different drive variant.

Frequently asked questions

What is the SCIP number for this part?

SCIP 483516f7-5042-4d76-a918-d7fab20a54ce Finland.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863, REACH declared (contains substances > 0.1 mass percentage), and UL listed for 1 Hp heavy-duty and 1.5 Hp light-overload.

What is the normal-use output rating?

1.1 kW at 6.9 A, 200–240 V three-phase input.

MPN
3AXD50000162109