ABB 3AXD50000162123 Drive Module, R1 Frame, 2.2 kW, 9.8 A

MPN3AXD50000162123
Active

ABB drive module, R1 frame, 3-phase 200…240 V input, 2.2 kW / 9.8 A normal-use output, IP20, CAN interface.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000162123 — Electrical Output
ParameterValue
Output power, normal duty (Pn)2.2 kW
Output current, normal duty (In)9.8 A
Output power, heavy duty (PhD)1.5 kW
Output current, heavy duty (IhD)7.8 A
Output power, light-overload duty (PlD)2.2 kW
Output current, light-overload duty (IlD)9.3 A
Output power, heavy duty (UL, Hp)2 Hp
Output current, heavy duty (UL)7.5 A
Apparent power output3.9 kV·A
Output power, light-overload duty (UL, Hp)2 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)9.3 A
Standby loss15 W
Power consumption140 W

Electrical Input

3AXD50000162123 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98

Control & I/O

3AXD50000162123 — Control & I/O
ParameterValue
Digital inputs / outputs2 / 1
Communication protocolCAN
Analog inputs0
Analog outputs0
Hardware interfacesIndustrial Ethernet 0

Environmental

3AXD50000162123 — Environmental
ParameterValue
Temperature rating, max.Maximum 50 °C
Operating humidity5 ... 95
Altitude1000 m
Noise level63.10 dB(A)

Mechanical

3AXD50000162123 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR1
Mounting typeModule

Approvals

3AXD50000162123 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

The ABB 3AXD50000162123 is a current-production drive module in the R1 frame size, rated for 3-phase 200…240 V input. Normal-use output is 2.2 kW at 9.8 A; heavy-duty use derates to 1.5 kW at 7.8 A. Light-overload use matches normal-use power at 2.2 kW but draws 9.3 A. The unit includes the control unit, communicates over CAN, and is rated IP20 for panel-mount environments.

The normal-use output current of 9.8 A is the figure to size motor protection and cabling for continuous duty. Heavy-duty use at 7.8 A applies for applications requiring higher torque at low speed or frequent starts — the 1.5 kW power limit reflects that thermal headroom. Light-overload use at 9.3 A sits between normal and heavy-duty for intermittent overload profiles. The 0.98 power factor and 140 W power consumption give the panel designer the numbers for upstream transformer and cooling sizing. Standby loss of 15 W matters for systems that idle for long periods — it's the heat the enclosure must shed even when the drive isn't running a load.

Current-production part. The R1 frame and CAN interface are stable.

Frequently asked questions

What is the SCIP number for this part?

The SCIP number is 483516f7-5042-4d76-a918-d7fab20a54ce Finland.

What compliance documentation is available?

RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (dated 20230303). REACH declaration confirms substances above 0.1 mass percentage (dated 20250905). UL technical ratings cover heavy-duty and light-overload use at 2 Hp.

What are the key output ratings?

Normal-use output is 2.2 kW at 9.8 A; heavy-duty use is 1.5 kW at 7.8 A; light-overload use is 2.2 kW at 9.3 A.

MPN
3AXD50000162123