Skip to main content
ABB 3AXD50000268306 — AC Drive (VFD) 240V

ABB 3AXD50000268306 ACQ580-01-04A6-2+P918 Drive, Frame R1, 2

MPN3AXD50000268306
Active

ABB ACQ580-01-04A6-2+P918, LV AC wall-mounted drive, 208-240 V 3-phase, Frame R1, IP21, NEMA Type 1, IE2, 13 W standby loss.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Input

3AXD50000268306 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Electrical Output

3AXD50000268306 — Electrical Output
ParameterValue
Apparent power output1.8 kV·A
Efficiency class (IE)IE2
Standby loss13 W

Environmental

3AXD50000268306 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C

Mechanical

3AXD50000268306 — Mechanical
ParameterValue
Degree of protection (IP)IP21
Enclosure type (NEMA)Type1
Frame sizeR1
Mounting typeWall-mounting

Product details

The ABB 3AXD50000268306 is the order code for an ACQ580-01-04A6-2+P918 low-voltage AC wall-mounted drive for water and wastewater. It runs on 208-240 V three-phase input at 50/60 Hz and is rated for apparent power output of 1.8 kV·A. The drive ships in Frame R1. Standby loss sits at 13 W, which is low enough that forced ventilation in a typical wall-mount cabinet is optional unless other heat sources crowd the enclosure.

Installation constraints

Wall-mounting only — no flange or through-panel kit included. Ambient temperature must not exceed 40 °C; derate the output current if the cabinet runs hotter. The IE2 efficiency level meets the minimum for most variable-torque pump and fan loads; if your site requires IE3 or IE4 for energy credits, factor the drive loss into the motor selection.

Frequently asked questions

What is the frame size of this drive?

The frame size is R1, which is the smallest physical envelope in the ACQ580 series.

What is the standby loss of this drive?

Standby loss is 13 W. This is low enough that forced ventilation is optional in most indoor wall-mount cabinets unless other heat sources are present.

What input voltage and phases does this drive require?

It requires 208-240 V three-phase input at 50/60 Hz.