ABB 3AXD50000268795 — AC Drive (VFD) 240V

3AXD50000268795 ABB ACQ580-01-024A-2+B056+P918, 7.5 Hp IP55

MPN3AXD50000268795
Active

ABB ACQ580-01-024A-2+B056+P918, LV AC wall-mounted drive, 208-240 V 3-phase, 7.5 Hp light-overload, 24.2 A, IP55, NEMA Type12, IE2, Frame Size R2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Input

3AXD50000268795 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Electrical Output

3AXD50000268795 — Electrical Output
ParameterValue
Output power, light-overload duty (PlD)7.5 Hp
Output current, light-overload duty (IlD)24.2 A
Apparent power output9.6 kV·A
Efficiency class (IE)IE2
Standby loss14 W

Environmental

3AXD50000268795 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C

Mechanical

3AXD50000268795 — Mechanical
ParameterValue
Degree of protection (IP)IP55
Enclosure type (NEMA)Type12
Frame sizeR2
Mounting typeWall-mounting

Product details

The ABB ACQ580-01-024A-2+B056+P918 (3AXD50000268795) is a dedicated LV AC wall-mounted drive for water and wastewater applications, built on the ACQ580 platform. It operates on 208-240 V three-phase supply and delivers 7.5 Hp (24.2 A) under light-overload use, with an apparent power output of 9.6 kV·A. The IP55 / NEMA Type12 enclosure and Frame Size R2 make it suited for pump and fan control in wet or dusty environments — no additional cabinet needed if the ambient stays at or below 40 °C. Standby loss sits at 14 W, which is modest for a drive this size and matters for energy-conscious installations.

Installation constraints

Wall-mounting is the intended method — no floor stand required. The IP55 / NEMA Type12 rating means the drive is sealed against dust and low-pressure water jets, so it can be mounted directly on the wall near the motor, provided the ambient temperature does not exceed 40 °C. The Frame Size R2 determines the mounting footprint and cable entry layout; verify the physical dimensions against your panel or wall space before ordering. The 14 W standby loss is dissipated as heat, so adequate ventilation around the enclosure is needed — do not box it into a tight alcove without airflow.

Efficiency and overload

Rated IE2 efficiency, which is the baseline for this class. The light-overload rating (24.2 A / 7.5 Hp) is the continuous operating point for pump and fan curves; if your motor draws more than that, you need to step up to the next frame size.

Frequently asked questions

What is the frame size of 3AXD50000268795?

The frame size is R2.

What is the standby loss of this drive?

The standby loss is 14 W.

What compliance documentation is available for this drive?

The ACQ580 series carries RoHS, REACH, UL, and IEC declarations. Request the specific certificates with your RFQ.

MPN
3AXD50000268795