The 3AXD50000284825: The 5 Hp / 16.7 A light-overload UL rating is the number that decides motor fit — this drive is sized for a 5 Hp motor at 230 V three-phase under light-overload duty (typically 110 % current for 60 s). The 6.7 kV·A apparent power confirms the same sizing. Standby loss sits at 13 W, so panel heat load is modest even if the drive is idle for long periods. Ambient max of 40 °C is standard for a wall-mounted enclosure; derating applies above that.
ABB 3AXD50000284825 ACH580-01 HVAC Drive, 5 Hp, 16.7 A, 230
MPN3AXD50000284825
Active
ABB ACH580-01 HVAC drive, order code 3AXD50000284825, frame size R1, 5 Hp light-overload UL output, 16.7 A, 208-240 V, IP21, wall-mounted.
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
Electrical Input
| Parameter | Value |
|---|---|
| Input voltage range | 208 ... 240 V |
| Number of phases | 3-phase |
| Frequency | 50/60 Hz |
Electrical Output
| Parameter | Value |
|---|---|
| Apparent power output | 6.7 kV·A |
| Output power, light-overload duty (UL, Hp) | 5 Hp |
| Efficiency class (IE) | IE2 |
| Output current, light-overload duty (UL) | 16.7 A |
| Standby loss | 13 W |
Environmental
| Parameter | Value |
|---|---|
| Temperature rating, max. | Maximum 40 °C |
Mechanical
| Parameter | Value |
|---|---|
| Degree of protection (IP) | IP21 |
| Enclosure type (NEMA) | Type1 |
| Frame size | R1 |
| Mounting type | Wall-mounted |
Product details
Frequently asked questions
What is the standby loss of this drive?
Standby loss is 13 W. That is the power the drive consumes when the motor is stopped but the DC bus is still energized — useful for panel heat-load calculations.
MPN
3AXD50000284825