Skip to main content
ABB 3AXD50000285044 — AC Drive (VFD) 600V

ABB 3AXD50000285044 ACH580-01 HVAC Drive, 100 Hp, 99 A, 575

MPN3AXD50000285044
Active

ABB ACH580-01 HVAC drive, 3AXD50000285044, Frame R7, 3-phase 500-600 V, 100 Hp light-overload, 99 A, IP21, NEMA 1, wall-mounted.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000285044 — Identification
ParameterValue
Frame sizeR7
3AXD50000285044 — Electrical (input)
ParameterValue
Input voltage range500 ... 600 V
Number of phases3-phase
Frequency range50/60 Hz
3AXD50000285044 — Output / Performance
ParameterValue
Output power (UL), light overload100 Hp
Output current (UL), light overload99 A
3AXD50000285044 — Mechanical
ParameterValue
Mounting typeWall-mounted
NEMA enclosure typeType1
3AXD50000285044 — Environmental
ParameterValue
Degree of protection (IEC, IP)IP21

Product details

The ABB 3AXD50000285044 is an ACH580-01 wall-mounted HVAC drive in Frame R7, rated for 3-phase 500-600 V input and delivering 100 Hp light-overload output at 99 A (UL, 575 V). That 99 A figure is the light-overload duty rating — the one that governs continuous fan and pump loads in HVAC applications, not the higher burst rating for short-duration peak demand. The IP21 enclosure and NEMA Type 1 rating mean it's suitable for clean indoor environments — no washdown, no dust. Wall-mounting keeps floor space clear, but the R7 frame is substantial; plan for adequate wall anchoring and clearance for the heatsink airflow. Runs on 50/60 Hz line frequency, so it's at home on either 50 Hz or 60 Hz grids without derating — common for HVAC drives that ship globally.

This is a current-production drive, sourced through standard ABB distribution channels.

Frequently asked questions

What is the frame size of this drive?

Frame R7. That's a physical size class that determines mounting hole pattern, heatsink dimensions, and wiring access — verify panel clearance against the ACH580-01 R7 outline drawing before committing the layout.

What input voltage and frequency does it accept?

3-phase 500-600 V at 50/60 Hz. The wide voltage range covers 480 V, 575 V, and 600 V nominal grids without a transformer tap change.

What is the light-overload output rating?

100 Hp at 99 A (UL, 575 V). This is the continuous rating for variable-torque loads like fans and pumps — the rating that matters for sizing the drive to the motor nameplate.

MPN
3AXD50000285044