Skip to main content
ABB 3AXD50000296569 — AC Drive (VFD) 240V

ABB 3AXD50000296569 ACH580-01 VFD, 40 Hp 114 A 230 V

MPN3AXD50000296569
Active

ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 3AXD50000296569, 40 Hp light-overload, 114 A, 208-240 V 3-phase, Frame R5, IP21, NEMA 1.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Input

3AXD50000296569 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Electrical Output

3AXD50000296569 — Electrical Output
ParameterValue
Apparent power output45 kV·A
Output power, light-overload duty (UL, Hp)40 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)114 A
Standby loss19 W

Environmental

3AXD50000296569 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C

Mechanical

3AXD50000296569 — Mechanical
ParameterValue
Degree of protection (IP)IP21
Enclosure type (NEMA)Type1
Frame sizeR5
Mounting typeWall-mounted

Product details

The ABB 3AXD50000296569 is an ACH580-01-114A-2 LV AC wall-mounted drive built for HVAC applications. It delivers 40 Hp at light-overload (114 A output) on a 208-240 V 3-phase supply, frame size R5. The enclosure is NEMA Type1 with IP21 protection, so it's suited for indoor panel or machine-mounted installations where dust and dripping water are controlled. Standby loss sits at 19 W — a figure to keep in mind for panel heat calculations, especially in a multi-drive lineup.

The headline number is the UL light-overload rating: 40 Hp at 114 A. That's the continuous current the drive can deliver for variable-torque HVAC loads (fans, pumps) without needing to oversize. The input voltage range is 208-240 V, 50/60 Hz — standard North American low-voltage mains. Efficiency is IE2, which meets the base level for many commercial HVAC specs. Maximum ambient is 40 °C; above that you'll need to derate output current per the drive's thermal curve. The 19 W standby loss is what the drive dissipates when the motor is stopped but the DC bus is still powered — relevant for energy code compliance and panel ventilation sizing.

Frequently asked questions

What is the frame size of this drive?

Frame size is R5.

What is the standby loss?

Standby loss is 19 W.

What enclosure and protection rating does it carry?

NEMA Type1 enclosure with IP21 degree of protection.

MPN
3AXD50000296569