ABB 3AXD50000296804 — AC Drive (VFD) 240V

ABB 3AXD50000296804 ACH580-01 HVAC Drive, 74.8 A, IP55

MPN3AXD50000296804
Active

ABB ACH580-01 series, LV AC wall-mounted HVAC drive, 74.8 A, 208-240 V, IP55, Frame R4.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000296804 — Electrical Output
ParameterValue
Output current, normal duty (In)74.8 A
Output power, light-overload duty (PlD)25 Hp
Apparent power output30 kV·A
Efficiency class (IE)IE2
Standby loss17 W

Electrical Input

3AXD50000296804 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Environmental

3AXD50000296804 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C

Mechanical

3AXD50000296804 — Mechanical
ParameterValue
Degree of protection (IP)IP55
Enclosure type (NEMA)Type12
Frame sizeR4
Mounting typeWall-mounting

Product details

The ABB 3AXD50000296804 is the order code for an ACH580-01-075A-2+B056, a low-voltage AC wall-mounted drive built for HVAC fan and pump control. It delivers 74.8 A continuous output on a 208-240 V three-phase supply, rated for 25 Hp in light-overload use. The R4 frame carries an IP55 enclosure — suitable for washdown or dusty environments without a separate cabinet.

The 74.8 A normal-use output current (In) is the number that decides cable sizing and upstream protection — not the horsepower figure. On a 208 V supply that current supports roughly 25 Hp; on 240 V the same current yields higher torque margin. Standby loss of 17 W is low for this frame class, meaning the drive's internal cooling fan and control electronics draw under 20 W when the motor is stopped. The IE2 efficiency level is the drive's own internal losses, not the motor's — expect around 97-98% efficiency at full load.

This part carries an active lifecycle status — ABB still manufactures the ACH580-01 series, and the 3AXD50000296804 order code is current. No last-time-buy or successor notice applies.

Wall-mounting is the intended method — the R4 frame has integral mounting points and a gland plate for cable entry. The IP55 rating means it can be hosed down from any direction, so it lives directly on the wall in a plant floor or rooftop HVAC unit without an extra enclosure. Maximum ambient temperature is 40 °C; above that, derate the output current per the drive's thermal curve. The NEMA Type12 equivalent covers indoor use against dust and dripping liquids.

Frequently asked questions

What is the frame size of this drive?

Frame size R4. That determines the physical footprint, mounting hole pattern, and gland plate layout for cable entry.

What is the standby power loss?

17 W. This is the power the drive consumes when the motor is stopped but the control electronics and cooling fan remain powered.

What compliance documentation is available?

The drive carries WEEE Category 4 (Large Equipment) classification. Standard ABB declarations for CE, UKCA, and RoHS are provided with the unit; UL listing applies to the ACH580-01 series.

MPN