Skip to main content
ABB 3AXD50000296859 — AC Drive (VFD) 240V

ABB 3AXD50000296859 ACH580-01 HVAC Drive, 211 A, 208-240 V

MPN3AXD50000296859
Active

ABB ACH580-01-211A-2+B056, LV AC wall-mounted drive for HVAC, 211 A, 208-240 V, IP55, NEMA 12, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000296859 — Electrical Output
ParameterValue
Output current, normal duty (In)211 A
Output power, light-overload duty (PlD)75 Hp
Apparent power output84 kV·A
Efficiency class (IE)IE2
Standby loss22 W

Electrical Input

3AXD50000296859 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Environmental

3AXD50000296859 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C

Mechanical

3AXD50000296859 — Mechanical
ParameterValue
Degree of protection (IP)IP55
Enclosure type (NEMA)Type12
Frame sizeR7
Mounting typeWall-mounting

Product details

The 3AXD50000296859 is an ABB ACH580-01 HVAC drive in frame size R7, wall-mounted, rated for 211 A normal use on a 208-240 V three-phase supply. That output current supports light-overload motor loads up to 75 Hp. The 84 kVA apparent power rating gives the headroom needed for fan and pump starts without oversizing the drive.

IP55 and NEMA Type 12 enclosure means the drive is sealed against dust and low-pressure water jets — suitable for washdown areas or outdoor installations under a roof. Maximum ambient temperature is 40 °C; above that, derate the output current per the drive's thermal curve. The wall-mounting footprint for frame R7 requires a flat, rigid surface with clearance for the cooling fins and cable entry glands.

Efficiency and standby

Rated IE2 efficiency class — this is the standard for HVAC drives in most regions; no premium-efficiency premium here. Standby loss is 22 W, which matters for continuous-operation installations where the drive idles between duty cycles. The drive operates on 50/60 Hz supply without configuration changes.

Frequently asked questions

What is the frame size and what does it mean for mounting?

Frame size R7. This is a wall-mounted drive requiring a flat surface with adequate clearance for cooling and cable entry. The physical dimensions are consistent with the R7 frame in the ACH580 family.

What is the standby power loss?

Standby loss is 22 W. This is the power dissipated when the drive is powered but not running a motor — relevant for energy-conscious installations or UPS-backed systems.

MPN
3AXD50000296859