The 3AXD50000417797: The enclosure is IP55 / NEMA Type 12, making it suitable for washdown areas or dusty mechanical rooms without an additional cabinet. Standby loss is 13 W, and full-load power consumption runs 53 W. Built-in BACnet communication handles BMS integration directly, and the drive ships with the control unit included — no separate order for the keypad or logic board.
The normal-use output current of 4.7 A at 0.75 kW is the continuous rating for standard HVAC loads. Light-overload use is 4.6 A / 0.75 kW, essentially matching normal use but with a slightly lower current ceiling for cyclic loads. Efficiency class IE2 is the standard for this drive size. The apparent power output is 1.9 kV·A, useful for sizing upstream transformer or feeder.
Two analog inputs and two analog outputs are available for feedback or setpoint signals. Digital I/O counts six inputs and three outputs, enough for basic start/stop, fault reset, and status indication without an expansion module. No industrial Ethernet interface is fitted as standard — BACnet is the only fieldbus on board. For PROFINET or EtherNet/IP, an option module would need to be added externally.
SCIP number 12216470-2923-46fb-9b3c-c7084d490da0 Finland is registered for the part, supporting EU waste framework reporting.