Skip to main content
ABB 3AXD50000417889 — AC Drive (VFD) 240V

3AXD50000417889 ACH580-01 HVAC Drive, 22 kW, 89 A, 230 V

MPN3AXD50000417889
Active

ABB ACH580-01 wall-mounted HVAC drive, 22 kW normal use, 89 A output, 200-240 V 3-phase, IP55, NEMA 12, BACnet, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000417889 — Electrical Output
ParameterValue
Output power, normal duty (Pn)22 kW
Output current, normal duty (In)89 A
Output power, heavy duty (PhD)18.5 kW
Output current, heavy duty (IhD)75 A
Output power, light-overload duty (PlD)22.0 kW
Output current, light-overload duty (IlD)88 A
Apparent power output35 kV·A
Efficiency class (IE)IE2
Standby loss19 W
Power consumption876 W

Electrical Input

3AXD50000417889 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Control & I/O

3AXD50000417889 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolBACNET
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0

Environmental

3AXD50000417889 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
Operating humidity95

Mechanical

3AXD50000417889 — Mechanical
ParameterValue
Degree of protection (IP)IP55
Enclosure type (NEMA)Type12
Frame sizeR5
Mounting typeWall-mounted

Approvals

3AXD50000417889 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

Drive selection memo for a 22 kW HVAC fan or pump

The ABB 3AXD50000417889 is a wall-mounted drive sized for a 22 kW motor at 200-240 V three-phase input. Normal-use output current is 89 A; heavy-duty use drops to 18.5 kW / 75 A for tougher loads like positive-displacement pumps. Light-overload use is rated 22.0 kW / 88 A. The drive includes a control unit and is frame size R5.

The 200-240 V input and 3-phase output match North American 208/230 V commercial supply. The 89 A normal-use rating handles a 22 kW motor at full load; if your load profile is heavy-duty (e.g., high starting torque), the drive is rated 75 A continuous. Standby loss is 19 W, which matters for energy code compliance on continuously powered drives. Efficiency is IE2. Enclosure is IP55 / NEMA Type12, so it's suitable for indoor washdown or dusty environments — think HVAC mechanical rooms or light industrial floors. Ambient temperature max is 40 °C; operating humidity up to 95% RH. Wall-mounted, so no floor space needed. Built-in BACnet communication (no Industrial Ethernet interface) makes this a direct fit for building management system integration. Two analog inputs and two analog outputs cover a speed reference and feedback; six digital inputs and three digital outputs handle start/stop, fault reset, and status. The drive includes a lithium coin cell (CR2032, 220 mAh) for real-time clock backup.

Frequently asked questions

What is the SCIP number for this drive?

SCIP number is 567c5ced-c536-4a8b-933d-885c159a15d8, registered in Finland.

What compliance documentation is available?

RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863; REACH declaration confirms substances above 0.1% mass percentage. RoHS date 20240508, REACH date 20250905.

MPN