The 3AXD50000418138: The drive accepts 47.5–63 Hz line frequency and draws 230 W at rated load. Standby loss sits at 13 W — worth noting if the drive idles for long periods. Efficiency is rated IE2.
Normal-use output current is 16.9 A; light-overload use pushes that to 16.7 A. Heavy-duty use drops to 10.6 A — that's the number to size against if the motor runs a pump with variable head or frequent starts. Apparent power output is 7.2 kV·A. Enclosure is IP55 with NEMA Type 12, so it handles hose-down and dust in treatment plants. Ambient temperature max is 40 °C; altitude rating goes to 4000 m — no derate worry at typical plant elevations. Operating humidity spans 5–95% RH. The drive includes a control unit and communicates via CAN. It has 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs — enough for basic pump control with feedback. No onboard industrial Ethernet; that's a separate hardware interface count of 0.