ABB 3AXD50000462384 — AC Drive (VFD) 240V

ABB 3AXD50000462384 ACS580 Drive, Frame R1, 5 HP UL

MPN3AXD50000462384
Active

ABB ACS580 series, LV AC Packaged drive with disconnect means, Frame Size R1, 3-phase 208...240 V, NEMA Type 1, IP21, UL: 5 Hp Light-Overload / 3 Hp Heavy-Duty.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Input

3AXD50000462384 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz

Electrical Output

3AXD50000462384 — Electrical Output
ParameterValue
Output power, heavy duty (UL, Hp)3 Hp
Output current, heavy duty (UL)10.6 A
Output power, light-overload duty (UL, Hp)5 Hp
Output current, light-overload duty (UL)16.7 A

Mechanical

3AXD50000462384 — Mechanical
ParameterValue
Degree of protection (IP)IP21
Enclosure type (NEMA)Type1
Frame sizeR1

Product details

Drive selection memo — 3AXD50000462384

The ABB 3AXD50000462384 is a packaged LV AC drive from the ACS580 series, fitted with a built-in disconnect means. The Frame Size R1 defines the mechanical envelope — compact enough for panel layouts where space is tight, but check the mounting footprint against your existing backplate before committing the BOM line. The UL ratings tell the real story for motor sizing. Light-overload duty (typically for variable-torque loads like fans and pumps) is rated 5 Hp at 16.7 A. Heavy-duty use (constant-torque loads such as conveyors or positive-displacement pumps) drops to 3 Hp at 10.6 A. The heavy-duty figure governs the selection for any application that demands full torque at low speed or frequent starts — do not size off the light-overload number for a crusher or extruder.

NEMA Type 1 and IP21 mean this drive is intended for indoor, dry, non-condensing environments. No washdown capability, no outdoor rating. The NEMA 1 knockouts simplify conduit entry, but the panel builder must still maintain clearance for airflow per the ACS580 installation manual. Frequency rating of 50/60 Hz covers both 50 Hz and 60 Hz mains without derating, so the same unit works on a 50 Hz line in a global facility or a 60 Hz line in the Americas. No need to specify a regional variant for frequency.

Frequently asked questions

What is the frame size of 3AXD50000462384?

Frame Size R1. This is the smallest frame in the ACS580 series, suitable for the 5 Hp / 16.7 A rating at 240 V.

What input voltage and frequency does this drive accept?

Three-phase 208... 240 V at 50/60 Hz. It covers both 50 Hz and 60 Hz mains without derating.

What are the UL motor ratings for this drive?

Light-overload (variable torque): 5 Hp, 16.7 A. Heavy-duty (constant torque): 3 Hp, 10.6 A. The heavy-duty rating is the binding figure for demanding loads.

What enclosure type and IP rating does this drive have?

NEMA Type 1 with IP21 protection. Suitable for indoor, dry locations only — not rated for washdown or outdoor installation.

MPN
3AXD50000462384