ABB 3AXD50000463398 — AC Drive (VFD) 600V

ABB 3AXD50000463398 ACS580 Drive, 60 Hp, 62 A, 600 V

MPN3AXD50000463398
Active

ABB ACS580-0P-062A-6, LV AC Packaged Drive, 60 Hp Light-Overload, 62 A, 600 V, Frame R5, NEMA 1, IP21.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000463398 — Identification
ParameterValue
Frame sizeR5
3AXD50000463398 — Electrical (input)
ParameterValue
Input voltage range525 ... 575 V
Number of phases3-phase
Frequency range50/60 Hz
3AXD50000463398 — Output / Performance
ParameterValue
Output power (UL), light overload60 Hp
Output power (UL), heavy duty50 Hp
Output current (UL), light overload62 A
Output current (UL), heavy duty52 A
3AXD50000463398 — Mechanical
ParameterValue
NEMA enclosure typeType1
3AXD50000463398 — Environmental
ParameterValue
Degree of protection (IEC, IP)IP21

Product details

The ABB 3AXD50000463398 is an ACS580-0P-062A-6 LV AC packaged drive with disconnect means, rated for 60 Hp light-overload use at 62 A and 50 Hp heavy-duty at 52 A, on a 525 to 575 V three-phase supply. Frame size R5, NEMA 1 enclosure with IP21 protection. This is the variant with the built-in disconnect, so it saves a panel component and a wiring step on UL-listed installations.

The light-overload rating of 62 A at 60 Hp applies to variable-torque fans and centrifugal pumps where the drive only sees peak current during acceleration. Both ratings are UL-listed, so the drive lands on a UL 508A panel without a derate argument. Input voltage range of 525 to 575 V covers 480 V systems with a step-up transformer or direct 600 V class supplies. The 50/60 Hz frequency rating is standard for global installs, but the drive's DC bus and IGBTs are sized for the higher voltage class — verify the motor's winding insulation if reusing an existing 480 V motor on a 575 V bus.

NEMA 1 enclosure with IP21 protection means it is suitable for indoor, non-condensing environments — clean panel shop or dry machine room, not washdown or outdoor. Frame R5 is a floor-standing cabinet; plan for bottom cable entry and adequate clearance for the disconnect handle swing. The built-in disconnect is a rotary type, so the door interlock is handled by the drive chassis.

Frequently asked questions

What is the frame size of this drive?

Frame size R5. This is a floor-standing cabinet, not a wall-mount unit.

What are the heavy-duty and light-overload ratings?

Heavy-duty: 50 Hp, 52 A. Light-overload: 60 Hp, 62 A. Both are UL-listed.

What input voltage and frequency does this drive accept?

Three-phase 525 to 575 V at 50/60 Hz.