Skip to main content
ABB 3AXD50000760978 — AC Drive (VFD) 600V

ABB ACQ580-01-06A1-6 3AXD50000760978 Drive, 5 Hp, 6.1 A

MPN3AXD50000760978
Active

ABB ACQ580-01-06A1-6, 3AXD50000760978, LV AC wall-mounted drive, 3-phase, 500…600 V, 5 Hp light-overload, 6.1 A, NEMA Type 1, IP21, Frame R2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3AXD50000760978 — Identification
ParameterValue
Frame sizeR2

Electrical (input)

3AXD50000760978 — Electrical (input)
ParameterValue
Input voltage range500 ... 600 V
Number of phases3-phase
Frequency range50/60 Hz

Output / Performance

3AXD50000760978 — Output / Performance
ParameterValue
Output power (UL), light overload5 Hp
Output power (UL), heavy duty3 Hp
Output current (UL), light overload6.1 A
Output current (UL), heavy duty3 A

Mechanical

3AXD50000760978 — Mechanical
ParameterValue
NEMA enclosure typeType1

Environmental

3AXD50000760978 — Environmental
ParameterValue
Degree of protection (IEC, IP)IP21

Product details

The ABB 3AXD50000760978 is an ACQ580-01-06A1-6 LV AC wall-mounted drive, purpose-built for water and wastewater applications. It runs on 3-phase 500…600 V input at 50/60 Hz, and delivers 5 Hp (6.1 A) under light-overload use, or 3 Hp (3 A) for heavy-duty cycles. The NEMA Type 1 enclosure with IP21 protection suits indoor, non-condensing environments.

The light-overload rating (5 Hp, 6.1 A) is the number to size against for pump and fan duty — the heavy-duty figure (3 Hp, 3 A) applies when you need constant-torque headroom for conveyors or positive-displacement loads. Frame size R2 tells you the mechanical footprint and mounting hole pattern; verify it matches your panel layout before committing the BOM line.

Frequently asked questions

What is the frame size of this drive?

Frame size R2. This determines the mounting dimensions and panel cutout — verify against your existing layout.

What are the UL output ratings for this drive?

Light-overload: 5 Hp, 6.1 A. Heavy-duty: 3 Hp, 3 A. Size against the light-overload figure for pump/fan duty; use the heavy-duty number for constant-torque applications.

What input voltage and frequency does this drive accept?

3-phase 500…600 V at 50/60 Hz.

What enclosure type and protection rating does this drive have?

NEMA Type 1 enclosure with IP21 degree of protection. Suitable for indoor, non-condensing installations.