ABB 3AXD50000956647 — AC Drive (VFD) 240V

ABB 3AXD50000956647 ACH180 Micro Drive, 1.1 kW, 6.9 A, 230 V

MPN3AXD50000956647
Active

ABB ACH180-04S-06A9-1, LV AC micro drive module for HVAC, IEC: Pn 1.1 kW, 6.9 A, 230 V, UL: Pld 1.5 Hp, 6.6 A, 230 V, frame R1, IP20, BACnet.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical Output

3AXD50000956647 — Electrical Output
ParameterValue
Output power, normal duty (Pn)1.1 kW
Output current, normal duty (In)6.9 A
Output power, heavy duty (PhD)0.75 kW
Output current, heavy duty (IhD)4.5 A
Output power, light-overload duty (PlD)1.1 kW
Output current, light-overload duty (IlD)6.6 A
Output power, heavy duty (UL, Hp)1.0 Hp
Output current, heavy duty (UL)4.5 A
Apparent power output2.7 kV·A
Output power, light-overload duty (UL, Hp)1.5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)6.6 A
Standby loss- W

Electrical Input

3AXD50000956647 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases1-phase
Frequency47.5 ... 63 Hz
Power factor0.98

Control & I/O

3AXD50000956647 — Control & I/O
ParameterValue
Digital inputs / outputs4 / 2
Communication protocolBACNET
Analog inputs2
Analog outputs1
Hardware interfacesIndustrial Ethernet 0

Environmental

3AXD50000956647 — Environmental
ParameterValue
Temperature rating, max.Maximum 60 °C
Altitude2000 m
Noise level51.80 dB(A)

Mechanical

3AXD50000956647 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR1
Mounting typeModule

Approvals

3AXD50000956647 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

The 3AXD50000956647: Normal-use output (Pn 1.1 kW, In 6.9 A) is the continuous rating for typical fan and pump curves. Heavy-duty use (PhD 0.75 kW, IhD 4.5 A) applies when the load demands higher peak torque or a constant-torque profile — a positive-displacement pump or a small conveyor, for example. Light-overload use (PlD 1.1 kW, IlD 6.6 A) sits between the two; the 6.6 A figure is slightly below the normal-use 6.9 A, so for a straight fan load the normal-use number is the one to size against.

Fieldbus and I/O

BACnet is the onboard protocol — no option card needed. That makes this drive a direct fit for building-automation networks where the BMS talks BACnet MS/TP or BACnet/IP. Two analog inputs and one analog output handle duct static-pressure transducers or valve feedback; the 4 digital inputs and 2 digital outputs cover start/stop, fault reset, and run-status handshakes. No industrial Ethernet interface on this variant (0 hardware interfaces for Industrial Ethernet), so if the plant standard is PROFINET or EtherNet/IP, this isn't the drop. The drive communicates over BACnet only.

Frequently asked questions

What is the SCIP number for this drive?

SCIP number 030cdeeb-e61c-40db-b392-d77adebb2036 Finland is listed for EU waste reporting.

What is the maximum operating altitude?

Rated for 2000 m altitude without derating.

MPN
3AXD50000956647