Skip to main content
ABB 3AXD50001002619 — AC Drive (VFD) 240V

ABB 3AXD50001002619 ACH580 HVAC Drive, 1.1 kW, IP66

MPN3AXD50001002619
Active

ABB ACH580-01 series, LV AC wall-mounted drive, 1.1 kW, 6.7 A, 200-240 V, IP66, NEMA 4X, frame R1, BACnet.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50001002619 — Electrical Output
ParameterValue
Output power, normal duty (Pn)1.1 kW
Output current, normal duty (In)6.7 A
Output power, heavy duty (PhD)0.75 kW
Output current, heavy duty (IhD)4.6 A
Output power, light-overload duty (PlD)1.1 kW
Output current, light-overload duty (IlD)6.6 A
Apparent power output2.7 kV·A
Output power, light-overload duty (UL, Hp)1.5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)6.6 A
Standby loss13 W
3AXD50001002619 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001002619 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolBACNET
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001002619 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001002619 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Frame sizeR1
Mounting typeWall-mounted

Product details

The 3AXD50001002619: Lifecycle status is active, so this is a current-production SKU — no last-time-buy or end-of-life clock.

BACnet MS/TP is the onboard protocol, so this drive talks directly to a building automation system without a gateway. Two analog inputs and two analog outputs handle speed reference and feedback loops. The six digital inputs and three digital outputs cover start/stop, fault reset, and status indication. Power factor is 0.98, which means the drive draws near-sinusoidal current from the line — no need for external harmonic filters in most HVAC specs. Frequency range is 47.5 to 63 Hz, so it tolerates weak or generator-fed grids.

Integration notes

Wall-mounted with frame R1 — expect a compact unit that fits a standard backplate. The IP66 / NEMA 4X enclosure allows outdoor or washdown installation; no rain hood required for most locations. The control unit is included, so no separate panel for the keypad or I/O terminals. The lithium coin cell (CR2032, 220 mAh) keeps the real-time clock and parameter backup alive during power loss.

Frequently asked questions

What is the frame size and enclosure rating?

Frame size is R1, and the enclosure is IP66 / NEMA 4X — suitable for washdown and outdoor installation.

What communication protocol does this drive support?

BACnet MS/TP is the onboard protocol, allowing direct connection to building automation systems.

What are the output power ratings for different duty cycles?

Normal use: 1.1 kW / 6.7 A. Heavy-duty use: 0.75 kW / 4.6 A. Light-overload use: 1.1 kW / 6.6 A. UL ratings: 1.5 Hp / 6.6 A.

MPN
3AXD50001002619