Skip to main content
ABB 3AXD50001002817 — AC Drive (VFD) 240V

ABB 3AXD50001002817 ACQ580-01 Drive, 1.1 kW, IP66

MPN3AXD50001002817
Active

ABB ACQ580-01 wall-mounted drive, 3AXD50001002817, 1.1 kW normal use, 6.7 A, 200-240 V, IP66/NEMA 4X, frame R1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001002817 — Electrical Output
ParameterValue
Output power, normal duty (Pn)1.1 kW
Output current, normal duty (In)6.7 A
Output power, heavy duty (PhD)0.75 kW
Output current, heavy duty (IhD)4.6 A
Output power, light-overload duty (PlD)1.1 kW
Output current, light-overload duty (IlD)6.6 A
Apparent power output2.7 kV·A
Output power, light-overload duty (UL, Hp)1.5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)6.6 A
Standby loss13 W
3AXD50001002817 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001002817 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001002817 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001002817 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Frame sizeR1
Mounting typeWall-mounted

Product details

The 3AXD50001002817: Normal-use output is 1.1 kW / 6.7 A; heavy-duty drops to 0.75 kW / 4.6 A. Light-overload stays at 1.1 kW / 6.6 A, which matches the UL 1.5 Hp rating. If your load profile cycles hard, size on the heavy-duty figure. Standby loss is 13 W — negligible for a continuously powered panel, but worth noting for battery-backed installations. Power factor 0.98 at rated load.

I/O and comms at a glance

Two analog inputs, two analog outputs. Six digital inputs, three digital outputs. Communication is CAN — no onboard Ethernet, so plan for a gateway if your control network is PROFINET or EtherNet/IP. The CR2032 lithium coin keeps the real-time clock alive; it's a standard cell, easy to replace during annual PM.

Frequently asked questions

What is the frame size and enclosure rating?

Frame R1, IP66, NEMA Type 4X. Suitable for wall mounting in washdown or outdoor enclosures.

What are the key electrical ratings?

Normal use: 1.1 kW, 6.7 A. Heavy-duty: 0.75 kW, 4.6 A. Input 200-240 V three-phase, 47.5-63 Hz.

What communication protocol does it support?

CAN. No industrial Ethernet interface on this variant.

MPN