Skip to main content
ABB 3AXD50001002831 — AC Drive (VFD) 240V

ABB 3AXD50001002831 ACQ580-01 VFD, 4 kW, 16.9 A, 230 V

MPN3AXD50001002831
Active

ABB ACQ580-01 wall-mounted drive, 3AXD50001002831, 4 kW normal use, 16.9 A output, 200-240 V 3-phase, IP66, NEMA 4X, CAN.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001002831 — Electrical Output
ParameterValue
Output power, normal duty (Pn)4 kW
Output current, normal duty (In)16.9 A
Output power, heavy duty (PhD)3 kW
Output current, heavy duty (IhD)10.6 A
Output power, light-overload duty (PlD)4 kW
Output current, light-overload duty (IlD)16.7 A
Apparent power output7.2 kV·A
Output power, light-overload duty (UL, Hp)5 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)16.7 A
Standby loss13 W
3AXD50001002831 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001002831 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001002831 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001002831 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Frame sizeR1
Mounting typeWall-mounted

Product details

The ABB 3AXD50001002831 is an ACQ580-01 wall-mounted drive sized for 4 kW normal-use output at 16.9 A, 200-240 V three-phase input. Heavy-duty rating drops to 3 kW, 10.6 A — sized for pump and fan profiles in water/wastewater duty. Frame R1, wall-mount, IP66 / NEMA 4X enclosure handles washdown environments without a separate cabinet.

Input and I/O constraints

Runs on 200-240 V three-phase, 47.5-63 Hz. No built-in Ethernet — communication is CAN only. Two analog inputs, two analog outputs, six digital inputs, three digital outputs. No industrial Ethernet interface on this variant; plan for a CAN bus master or gateway if you need higher-level fieldbus integration.

Efficiency and losses

IE2 efficiency level. Standby loss is 13 W. Power factor 0.98. Ambient temperature max 40 °C. Lithium coin cell (CR2032, 220 mAh) on board for parameter backup.

Frequently asked questions

What is the frame size and enclosure rating?

Frame size R1, wall-mounted, IP66 / NEMA Type 4X enclosure.

What communication protocol does this drive use?

CAN protocol only — no industrial Ethernet interface on this variant.

What are the normal-use and heavy-duty output ratings?

Normal use: 4 kW, 16.9 A. Heavy-duty use: 3 kW, 10.6 A. Light-overload use: 4 kW, 16.7 A (UL: 5 Hp, 16.7 A).

MPN