Duty ratings and overload
The 3AXD50001003067: Normal-use output is 11 kW / 46.7 A. Light-overload use (PlD) matches the normal-use power at 11 kW / 46.2 A, so the drive does not derate for variable-torque fans or centrifugal pumps. UL light-overload rating is 15 Hp at 46 A.
Six digital inputs, three digital outputs. Two analog inputs and two analog outputs — enough for a speed reference and a feedback transducer without an expansion module. Communication is CAN-based; no onboard Ethernet, so plan for a fieldbus adapter if the line uses PROFINET or EtherNet/IP. Standby loss is 15 W; power factor 0.98.