Skip to main content
ABB 3AXD50001003074 — AC Drive (VFD) 240V

ABB 3AXD50001003074 ACS580 Drive, 15 kW, 60 A, IP66

MPN3AXD50001003074
Active

ABB ACS580-01-060A-2+B063, LV AC industrial wall-mounted single drive, 15 kW, 60 A, 230 V, IP66, Type4X, frame R3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50001003074 — Electrical Output
ParameterValue
Output power, normal duty (Pn)15 kW
Output current, normal duty (In)60 A
Output power, heavy duty (PhD)11 kW
Output current, heavy duty (IhD)46.2 A
Output power, light-overload duty (PlD)15 kW
Output current, light-overload duty (IlD)59.4 A
Apparent power output23.9 kV·A
Output power, light-overload duty (UL, Hp)20 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)59 A
Standby loss15 W
3AXD50001003074 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001003074 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001003074 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001003074 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Frame sizeR3
Mounting typeWall-mounted

Product details

The ABB 3AXD50001003074 is an ACS580-01-060A-2+B063 LV AC industrial wall-mounted single drive, rated for 15 kW normal-use output at 60 A on a 200–240 V three-phase supply, with a frequency range of 47.5–63 Hz. It ships as a control unit included, in frame size R3, with IP66 and NEMA Type4X enclosure protection.

Normal-use output current is 60 A (15 kW), with a heavy-duty rating of 46.2 A (11 kW) and a light-overload rating of 59.4 A (15 kW). The UL light-overload rating is 20 Hp at 59 A. Apparent power output is 23.9 kV·A. Power factor is 0.98, standby loss is 15 W, and efficiency is IE2. These ratings define the drive's capability for continuous motor loads versus cyclic or heavy-start applications.

The drive provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is via CAN protocol; there are no industrial Ethernet interfaces. The ambient temperature limit is 40 °C maximum.

Frequently asked questions

What is the frame size and enclosure protection?

Frame size is R3. Enclosure is IP66 and NEMA Type4X, suitable for wall mounting in washdown or outdoor environments.

What are the normal-use and heavy-duty output ratings?

Normal use: 15 kW, 60 A. Heavy-duty use: 11 kW, 46.2 A. Light-overload use: 15 kW, 59.4 A. UL light-overload: 20 Hp, 59 A.

What communication protocol does this drive use?

It uses CAN protocol. There are no industrial Ethernet interfaces on this variant.

MPN
3AXD50001003074