Skip to main content
ABB 3AXD50001004682 — AC Drive (VFD) 240V

ABB 3AXD50001004682 ACQ580-01 VFD, 3 kW, 12 A, IP66

MPN3AXD50001004682
Active

ABB ACQ580-01 series, LV AC wall-mounted drive, 3AXD50001004682, 3 kW / 12 A normal use, 200-240 V 3-phase, IP66, NEMA 4X, frame R1, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001004682 — Electrical Output
ParameterValue
Output power, normal duty (Pn)3 kW
Output current, normal duty (In)12 A
Output power, heavy duty (PhD)2.2 kW
Output current, heavy duty (IhD)7.5 A
Output power, light-overload duty (PlD)3 kW
Output current, light-overload duty (IlD)11.8 A
Apparent power output4.8 kV·A
Output power, light-overload duty (UL, Hp)3 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)10.6 A
Standby loss13 W
3AXD50001004682 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001004682 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001004682 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001004682 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Frame sizeR1
Mounting typeWall-mounted

Product details

The 3AXD50001004682: Enclosure is IP66 / NEMA 4X, so it handles washdown environments and outdoor installation without a separate cabinet. Ambient max is 40 °C; above that, derate per the thermal curve in the manual.

Onboard I/O: 6 digital inputs, 3 digital outputs, 2 analog inputs, 2 analog outputs. Communication is CAN-based — no onboard Ethernet (0 hardware interfaces for Industrial Ethernet), so if you need Modbus TCP or PROFINET, plan for an optional fieldbus adapter. The control unit is included, so you don't need to order it separately. Standby loss is 13 W — negligible for continuous operation but worth noting if the drive sits idle for long periods and you're tracking parasitic loads. Power factor is 0.98, so line-side filtering requirements are modest.

Frequently asked questions

What is the frame size and enclosure rating?

Frame size is R1. Enclosure is IP66 and NEMA Type 4X, suitable for washdown and outdoor use.

What are the key output ratings?

Normal-use output is 3 kW at 12 A. Heavy-duty use is 2.2 kW at 7.5 A. Light-overload use is 3 kW at 11.8 A. UL light-overload is 3 Hp at 10.6 A. Input voltage is 200-240 V three-phase.

Does it include a control unit?

Yes, the control unit is included with this order code.

What communication protocol does it support?

Onboard communication is CAN. There are no Industrial Ethernet interfaces, so an optional fieldbus adapter is needed for Ethernet-based protocols.

MPN
3AXD50001004682