The ABB 3AXD50001011116 is an ACQ580-31 ultra-low harmonic drive, wall-mounted, built for water and wastewater applications. It runs on 3-phase 208-240 V input and delivers 60 Hp (169 A) under UL light-overload duty. Frame R8, IP21, NEMA Type 1 enclosure.
The UL light-overload rating of 60 Hp at 169 A is the figure that governs motor sizing in North American installations — not the drive's nominal current, but the specific duty curve matched to pump and fan loads common in water/wastewater. The 208-240 V input range covers standard North American low-voltage three-phase supplies. Frame R8 is a physical mounting and wiring footprint; confirm cabinet cutout and bus bar spacing against the R8 dimension drawing before panel layout.