Specifications

3AXD50001108991 — Electrical Output
ParameterValue
Output power, normal duty (Pn)0.55 kW
Output current, normal duty (In)3.7 A
Output power, heavy duty (PhD)0.37 kW
Output current, heavy duty (IhD)2.4 A
Output power, light-overload duty (PlD)0.55 kW
Output current, light-overload duty (IlD)3.5 A
Output power, heavy duty (UL, Hp)0.5 Hp
Output current, heavy duty (UL)2.4 A
Apparent power output1.5 kV·A
Output power, light-overload duty (UL, Hp)0.75 Hp
Output current, light-overload duty (UL)3.5 A
Power consumption42 W
3AXD50001108991 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases1-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001108991 — Control & I/O
ParameterValue
Digital inputs / outputs4 / 2
Communication protocolBACNET
Analog inputs2
Analog outputs1
Hardware interfacesIndustrial Ethernet 0
3AXD50001108991 — Environmental
ParameterValue
Altitude2000 m
3AXD50001108991 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR0
Mounting typeModule

Product details

It delivers 0.55 kW normal-duty output at 3.7 A from a 200-240 V single-phase supply, with a BACnet communication interface. Frame size R0 keeps the panel footprint compact; the module mounts directly and draws 42 W at full load. Two analog inputs and one analog output handle sensor feedback; four digital inputs and two digital outputs manage start/stop and status signals. Rated for installation up to 2000 m altitude without derating, with IP20 protection for clean indoor environments. The open-type NEMA enclosure means it expects a panel or cabinet for environmental shielding.

Three duty curves are defined: normal use at 0.55 kW / 3.7 A, heavy-duty at 0.37 kW / 2.4 A, and light-overload at 0.55 kW / 3.5 A. The heavy-duty figure governs constant-torque loads like conveyors; normal and light-overload apply to variable-torque HVAC fans and pumps where peak current is brief. UL ratings mirror the IEC curves: 0.75 Hp normal / light-overload, 0.5 Hp heavy-duty, at the same current values. Power factor sits at 0.98, reflecting the active front-end typical of modern micro drives. Apparent power output is 1.5 kVA; input frequency range is 47.5-63 Hz.

The BACnet variant is a specific order code, not a field-configurable option, so confirm the communication protocol matches your BMS before committing the line item.

Integration notes

Single-phase 200-240 V input — no neutral required. The drive includes the control unit; no separate controller module is needed. No industrial Ethernet interface is fitted; communication is BACnet only, so verify your network segment supports MS/TP or BACnet/IP as implemented. Digital I/O: 4 inputs, 2 outputs. Analog: 2 inputs, 1 output. WEEE category 5 (small equipment under 50 cm) applies for end-of-life disposal compliance in EU markets.

Frequently asked questions

What are the key output ratings for this drive?

Normal duty: 0.55 kW / 3.7 A. Heavy-duty: 0.37 kW / 2.4 A. Light-overload: 0.55 kW / 3.5 A. UL equivalent: 0.75 Hp normal/light-overload, 0.5 Hp heavy-duty.

What communication protocol does this drive use?

BACnet. There is no industrial Ethernet interface on this variant.

What is the input voltage and phase requirement?

200-240 V single-phase, 47.5-63 Hz.

What is the altitude rating?

2000 m without derating.