Skip to main content
ABB 3AXD50001109271 — AC Drive (VFD) 240V

ABB 3AXD50001109271 ACS580 Drive, 11 kW, 46.7 A, IP66

MPN3AXD50001109271
Active

ABB ACS580-01 series, LV AC industrial wall-mounted single drive, 11 kW, 46.7 A, 230 V, IP66, NEMA 4X.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50001109271 — Electrical Output
ParameterValue
Output power, normal duty (Pn)11 kW
Output current, normal duty (In)46.7 A
Output power, heavy duty (PhD)7.5 kW
Output current, heavy duty (IhD)30.8 A
Output power, light-overload duty (PlD)11 kW
Output current, light-overload duty (IlD)46.2 A
Apparent power output18.6 kV·A
Output power, light-overload duty (UL, Hp)15 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)46 A
Standby loss15 W
3AXD50001109271 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001109271 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001109271 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001109271 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Mounting typeWall-mounted

Product details

The ABB 3AXD50001109271 is an ACS580-01 wall-mounted drive rated for 11 kW normal-duty output at 46.7 A on a 200–240 V three-phase supply. Heavy-duty use drops to 7.5 kW at 30.8 A; light-overload use holds at 11 kW, 46.2 A. The IP66 / NEMA 4X enclosure lets it sit on the wall in washdown or dusty environments without a separate cabinet.

Heavy-duty (30.8 A) covers the same motor if you need 150% overload for starting or peak events. The 0.98 power factor is the drive-side input figure — not the motor PF — and matters for line-side harmonic assessment.

The drive carries 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. Communication is CAN-based; there are no onboard industrial Ethernet interfaces. The control unit is included in the order code.

Frequently asked questions

What is the closest alternative to this drive in the same family?

The closest peer is another ACS580-01 variant with a different current rating or voltage class. The deciding factor is the motor full-load current — match the normal-duty output current (46.7 A) to your motor nameplate. No pin-compatible alternative exists; the entire drive is the replacement unit.

What does the order code include?

It includes the control unit as part of the drive assembly.

What is the power factor rating?

The drive-side input power factor is 0.98.

MPN
3AXD50001109271