Drive for water and wastewater duty
The ABB 3AXD50001109424 is an ACQ580-01 wall-mounted LV AC drive, purpose-built for water and wastewater applications. It delivers 1.1 kW normal-use output at 6.7 A on a 200–240 V three-phase supply, with a heavy-duty rating of 0.75 kW at 4.6 A for pump and fan loads that cycle hard. The IP66 / NEMA 4X enclosure stands up to washdown environments — rated for outdoor or wet-location installation without an extra cabinet.
Heavy-duty (PhD) at 0.75 kW applies when the motor sees repeated high-start-torque cycles — sizing to the heavy-duty figure ensures the drive doesn't trip on overload during a clogged-impeller restart. The UL light-overload figure (1.5 Hp, 6.6 A) matches the IEC normal-use current within rounding, so a single motor nameplate covers both standards. Power factor sits at 0.98, typical for a diode-front-end drive at full load; standby loss is 13 W — relevant for installations where the drive stays powered between pump cycles.
The drive includes 2 analog inputs, 2 analog outputs, and 6 digital inputs / 3 digital outputs — enough for a basic pump control scheme (level sensor, flow switch, start/stop, fault relay) without an expansion module. Communication is CAN-based; no onboard Ethernet port, so if the site runs Modbus TCP or PROFINET, plan for a fieldbus adapter. The control unit is included in the package, so no separate ordering step for the brain.