The ABB 3AXD50001109462 is a wall-mounted drive rated for 5.5 kW normal-use output at 24.5 A from a 200-240 V three-phase supply. It ships with the control unit included and carries IP66 / NEMA 4X protection. Heavy-duty cycle rating is 4 kW at 16.7 A; light-overload matches the normal-use figure at 24.2 A. UL listing shows 7.5 Hp at 24 A for the light-overload case.
The 0.98 power factor and IE2 efficiency class tell you this drive draws near-unity from the line at rated load — no power-factor correction caps needed upstream. Standby loss of 14 W is the heat it dumps into a panel or wall space when the motor is stopped; factor that into your ventilation calculation if the drive is in a sealed NEMA 4X cabinet. Maximum ambient is 40 °C. Apparent power rating is 9.8 kV·A. Built-in I/O: 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs.
This drive has IP66 / NEMA 4X enclosure and wall-mount format for pump stations and treatment plants. The included control unit arrives as a single line item.