The ABB 3AXD50001109486 is an ACQ580-01 wall-mounted LV AC drive rated 11 kW normal-duty output at 46.7 A on a 200–240 V three-phase supply. Light-overload use (the UL listing) comes in at 15 Hp, 46 A. The drive carries an IE2 efficiency level and a power factor of 0.98, which keeps the line-side draw clean for the transformer feeding the panel. It includes a control unit, two analog inputs and two analog outputs, plus six digital inputs and three digital outputs. Communication is handled via CAN — there is no onboard industrial Ethernet port, so if your plant network runs PROFINET or EtherNet/IP, you will need an optional fieldbus adapter module. The standby loss sits at 15 W, which is modest enough that you can leave it powered for a weekend without worrying about the panel heating up. The enclosure is rated IP66 and NEMA 4X, meaning it is dust-tight and can handle hose-down washdown environments. Wall-mounted, with a maximum ambient of 40 °C. The frequency range is 47.5 to 63 Hz, so it covers 50 Hz and 60 Hz grids without a firmware change.

ABB 3AXD50001109486 ACQ580-01 VFD, 11 kW, 46.7 A, 230 V, IP6
ABB ACQ580-01 wall-mounted LV AC drive, 3AXD50001109486, 11 kW normal duty, 46.7 A, 230 V, IP66, NEMA 4X.
Specifications
| Parameter | Value |
|---|---|
| Output power, normal duty (Pn) | 11 kW |
| Output current, normal duty (In) | 46.7 A |
| Output power, heavy duty (PhD) | 7.5 kW |
| Output current, heavy duty (IhD) | 30.8 A |
| Output power, light-overload duty (PlD) | 11 kW |
| Output current, light-overload duty (IlD) | 46.2 A |
| Apparent power output | 18.6 kV·A |
| Output power, light-overload duty (UL, Hp) | 15 Hp |
| Efficiency class (IE) | IE2 |
| Output current, light-overload duty (UL) | 46 A |
| Standby loss | 15 W |
| Parameter | Value |
|---|---|
| Input voltage range | 200 ... 240 V |
| Number of phases | 3-phase |
| Frequency | 47.5 ... 63 Hz |
| Power factor | 0.98 |
| Parameter | Value |
|---|---|
| Digital inputs / outputs | 6 / 3 |
| Communication protocol | CAN |
| Analog inputs | 2 |
| Analog outputs | 2 |
| Hardware interfaces | Industrial Ethernet 0 |
| Parameter | Value |
|---|---|
| Temperature rating, max. | Maximum 40 °C |
| Parameter | Value |
|---|---|
| Degree of protection (IP) | IP66 |
| Enclosure type (NEMA) | Type4X |
| Mounting type | Wall-mounted |
Product details
Frequently asked questions
What is the closest alternative to this drive?
The ACQ580-01 family includes other power ratings, but no pin-compatible drop-in exists at a different current level. If you need a different duty point, the same frame size may have a sibling with higher or lower output current — check the ABB ACQ580-01 selection table for the exact match to your load.
What does the drive include?
It includes a control unit. The listing also specifies a lithium coin cell (CR2032, 220 mAh, 3 V) for backup.
What is the power factor of this drive?
The power factor is 0.98, which is typical for a modern VFD with an active front end or good diode-bridge filtering.
What compliance documentation is available?
The drive carries UL ratings for light-overload use (15 Hp, 46 A). RoHS and REACH documentation should be available from ABB's compliance portal; no specific certificates are listed in this record, but the UL listing confirms third-party safety certification.