Specifications

3AXD50001109493 — Electrical Output
ParameterValue
Output power, normal duty (Pn)15 kW
Output current, normal duty (In)60 A
Output power, heavy duty (PhD)11 kW
Output current, heavy duty (IhD)46.2 A
Output power, light-overload duty (PlD)15 kW
Output current, light-overload duty (IlD)59.4 A
Apparent power output23.9 kV·A
Output power, light-overload duty (UL, Hp)20 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)59 A
Standby loss15 W
3AXD50001109493 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001109493 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001109493 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001109493 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Mounting typeWall-mounted

Product details

Environmental rating

The 3AXD50001109493: IP66 and NEMA 4X enclosure means this drive handles washdown environments directly — no separate cabinet required for water or dust ingress. Maximum ambient temperature is 40 °C. Wall-mounted form factor suits individual pump or fan installations where floor space is tight.

Built-in CAN protocol for drive-to-drive or drive-to-controller links. Two analog inputs and two analog outputs handle speed reference and feedback signals. Six digital inputs and three digital outputs cover start/stop, fault reset, and status indication. No onboard Ethernet — if you need fieldbus connectivity, plan for an optional module.

Efficiency and standby

IE2 efficiency class and a power factor of 0.98 keep line draw clean. Standby loss is 15 W — negligible for continuous operation but worth noting if the drive sits idle for extended periods.

Frequently asked questions

Does this drive include a control unit?

Yes, the listing includes the control unit. It is a complete package, not a power section alone.

What enclosure protection does it offer?

IP66 and NEMA 4X, suitable for washdown and outdoor installations without an additional cabinet.

MPN