Skip to main content
ABB 3AXD50001109653 — AC Drive (VFD) 240V

ABB 3AXD50001109653 ACH580-01 HVAC Drive, 3 kW, 12 A, IP66

MPN3AXD50001109653
Active

ABB ACH580-01 wall-mounted HVAC drive, 3AXD50001109653, 3 kW / 12 A normal use, 200-240 V 3-phase, IP66/NEMA 4X, BACnet, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50001109653 — Electrical Output
ParameterValue
Output power, normal duty (Pn)3 kW
Output current, normal duty (In)12 A
Output power, heavy duty (PhD)2.2 kW
Output current, heavy duty (IhD)7.5 A
Output power, light-overload duty (PlD)3 kW
Output current, light-overload duty (IlD)11.8 A
Apparent power output4.8 kV·A
Output power, light-overload duty (UL, Hp)3 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)10.6 A
Standby loss13 W
3AXD50001109653 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50001109653 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 3
Communication protocolBACNET
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50001109653 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
3AXD50001109653 — Mechanical
ParameterValue
Degree of protection (IP)IP66
Enclosure type (NEMA)Type4X
Mounting typeWall-mounted

Product details

HVAC drive, wall-mount, IP66

The ABB 3AXD50001109653 is an ACH580-01 wall-mounted LV AC drive for HVAC, rated 3 kW normal use at 12 A on 200-240 V three-phase input. Heavy-duty use is 2.2 kW / 7.5 A; light-overload use is 3 kW / 11.8 A (UL: 3 Hp / 10.6 A). The enclosure is IP66 / NEMA 4X, so it handles washdown and outdoor installs without a separate cabinet. Ambient limit is 40 °C.

BACnet and I/O

Built-in BACnet communication — no option card needed for BAS integration. The drive carries 2 analog inputs, 2 analog outputs, 6 digital inputs, and 3 digital outputs. No industrial Ethernet interface on this variant. The control unit is included.

Efficiency and standby

IE2 efficiency level. Standby loss is 13 W, which matters for energy code compliance on fan and pump loads that cycle frequently. Power factor is 0.98. Frequency range covers 47.5 to 63 Hz, so it handles 50/60 Hz grids.

The product status is active. No obsolescence notice or last-time-buy window is in effect.

Frequently asked questions

What are the key ratings for this drive?

Normal-use output is 3 kW / 12 A; heavy-duty is 2.2 kW / 7.5 A; light-overload is 3 kW / 11.8 A (UL: 3 Hp / 10.6 A). Input is 200-240 V three-phase, 47.5-63 Hz. Enclosure is IP66/NEMA 4X.

What communication protocol does this drive support?

BACnet is built in. No industrial Ethernet interface is present on this variant.

What is the standby power loss?

Standby loss is 13 W.

MPN
3AXD50001109653