Skip to main content
ABB A2A200CTL-4SB — Contactors

A2A200CTL-4SB A2A 2P 200A 10kAIC Breaker, Line/Load Lugs + S

MPNA2A200CTL-4SB
End of Life

Eaton A2A series, 2-pole 200A 10kAIC molded case circuit breaker, line/load lugs + shunt trip, A2A200CTL-4SB.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Product details

The A2A series is a compact thermal-magnetic breaker family used in panelboard and switchboard distribution for feeder and branch circuit protection. The 200A frame covers heavy lighting, motor control center feeders, and general power distribution loads up to that ampacity.

The 10 kAIC interrupting rating means it can safely clear a fault current up to 10,000 symmetrical amperes at its rated voltage — adequate for most secondary-side distribution in 480Y/277V or 240V delta panels, but not for high-fault-capacity service entrances where 25 kAIC or higher is required. The shunt trip (SB) allows remote tripping via a control voltage, typically wired to an emergency-stop circuit or fire-alarm relay. Line and load lugs are included, so no additional lug kit is needed for copper or aluminum conductors within the breaker's wire range.

Deployment Context

This breaker mounts into Eaton A2A-series panelboards or separate enclosures via the standard bolted connection pattern. The shunt trip requires a separate control power source (typically 120V or 24VDC, depending on the trip coil rating — verify the specific coil voltage marked on the unit). In a panel, the 2-pole 200A frame occupies two pole spaces and connects to the bus via the line-side lugs; load-side lugs feed the downstream circuit. For MRO planners: this is a line-item that, being eol_hot, should be cross-referenced to an active Eaton frame series (such as the G or J-frame) for any new BOM or expansion — keep this SKU only for existing installed-base repairs where form-factor and accessory wiring must match.

Frequently asked questions

Where can I buy A2A200CTL-4SB and get current pricing?

This part is sourced through independent surplus and broker channels against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a real-time sourcing check.

What is the interrupting rating of A2A200CTL-4SB?

The breaker is rated for 10 kAIC (10,000 symmetrical amperes interrupting capacity).

Does A2A200CTL-4SB include line and load lugs?

Yes. The description confirms it ships with line and load lugs plus a shunt trip accessory.

MPN
A2A200CTL-4SB