Skip to main content
ABB A45-40-00-80 — Contactors

A45-40-00-80 Non-Reversing Contactor, 70A, 4-Pole, EOL Hot

MPNA45-40-00-80
End of Life

Furnas/Siemens A45 series, Non-Reversing contactor, 4-pole, 70 amp, 230-240V AC coil, no auxiliary contacts.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A45-40-00-80 — Specifications
ParameterValue
TypeNon-Reversing

Product details

The Furnas/Siemens A45-40-00-80 is a 4-pole, non-reversing across-the-line block contactor rated 70 A with a 230-240 V AC coil and no auxiliary contacts. This is a panel-mount power switching device sized for motor and resistive loads up to its 70 A continuous rating — the 4-pole configuration lets it switch three phases plus a neutral or a second load circuit in a single block.

The 70 A rating governs the continuous current the main poles can carry in a standard industrial enclosure at 40 °C ambient — derate for higher panel temperatures or dense ganging. The 230-240 V AC coil (50/60 Hz) means the control circuit must supply that voltage range; a 24 VDC or 120 VAC coil will not pull this contactor in. Non-reversing type: no mechanical interlock for forward-reverse pairs, so if the application needs motor reversing, two of these plus an external interlock are required.

No auxiliary contact block is fitted; if feedback or status signaling is needed, an add-on side-mount aux stack must be ordered separately. The 4-pole layout with AC coil means the coil inrush and hold VA draw should be checked against the control transformer sizing, especially on a shared 240 V control bus.

Frequently asked questions

What is the A45-40-00-80 used for?

It is a 4-pole non-reversing block contactor rated 70 A with a 230-240 V AC coil, used for switching motor loads or resistive loads in industrial control panels where three-phase plus neutral or a second load circuit needs to be switched in one block.

Where can I buy the A45-40-00-80?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What does the non-reversing type mean for this contactor?

Non-reversing means the contactor has no built-in mechanical interlock for forward-reverse motor pairs. If the application requires motor reversing, two of these contactors plus an external interlock are needed.

MPN
A45-40-00-80