ABB ACS550-U1-097A-4+K466 — AC Drives (VFD)

ABB ACS550-U1-097A-4+K466 drive, 97 A / 56 kW

MPNACS550-U1-097A-4+K466
End of Life

ABB ACS550 series ACS550-U1-097A-4+K466 three-phase drive, 380-480 VAC at 97 A / 56 kW, Ethernet adaptor option, NEMA 1 / UL Type enclosure for US installation.

$6,714.10Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ACS550-U1-097A-4+K466 — Mechanical
ParameterValue
Weight27.22 kgs
ACS550-U1-097A-4+K466 — Other specifications
ParameterValue
Option 1Ethernet Adaptor
Option 2UL Type/NEMA 1
ConstructionUS Installation and NEMA Compliance
Output current ratingThree-Phase, 380-480 VAC, 50/60 HZ, 97 A, 56 KW

Product details

The drive and its load class

The ABB ACS550-U1-097A-4+K466 is a member of the ACS550 series of AC drives, configured here with the Ethernet adaptor option and a NEMA 1 / UL Type enclosure built for US installation. It is a three-phase output unit rated for 380-480 VAC at 50/60 Hz, delivering 97 A and 56 kW to the motor. That output envelope places it squarely in the 50–60 kW constant-torque window where fan, pump, and general-purpose induction motor loads typically land — sizing the drive to the motor nameplate first, then derating for ambient, switching frequency, and cable length, is the discipline that keeps it on the right side of its thermal curve.

What the option codes change

The +K466 suffix selects the Ethernet adaptor option, so the fieldbus interface ships installed. The NEMA 1 / UL Type enclosure rating targets indoor wall- or panel-mount in a clean industrial environment; it is not a sealed outdoor build. At 27.22 kg the unit is a one-person lift with a proper handle, but it is not a tabletop component — the panel layout needs to budget for the heat sink footprint and the clearance above and below the chassis for the cooling airflow the ACS550 line requires. Plan the gland plate entries for the motor output cable and the brake/chopper wiring so the output reactors or dV/dt filter, if the cable run demands one, sit as close to the drive terminals as the layout allows.

Frequently asked questions

What is the closest functional second-source to ACS550-U1-097A-4+K466?

On the same 380-480 V frame, ACS550-U1-096A-4 at 96 A is within a single amp of this drive and is the natural frame-class cross-shop candidate. ACS550-U1-114A-2 is a 208-240 VAC frame at 114 A, which is a different voltage class rather than a drop-in alternate.

MPN