Skip to main content
ABB ACS800-01-0016-5+E200+2L501 — AC Drives (VFD)

ABB ACS800-01-0016-5+E200+2L501 AC Drive, 13 kg

MPNACS800-01-0016-5+E200+2L501
End of Life

ABB ACS800-01-0016-5+E200+2L501 wall-mount low-voltage AC drive, +E200 and +2L501 option codes, 13.00 kg.

$5,189.93Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ACS800-01-0016-5+E200+2L501 — Mechanical
ParameterValue
Weight13.00 kgs

Product details

What lands on the panel when this code is ordered

The ABB ACS800-01-0016-5+E200+2L501 is a wall-mount low-voltage AC drive in the Drives / Motor Drives class under Motors & Motor Controls, ordered here with the +E200 and +2L501 option codes applied to the base unit. The full order code is what a buyer quotes on the BOM line. The +E200 and +2L501 suffixes are option identifiers that modify the base drive — +E200 generally points at an EMC/RFI filter stage arrangement and +2L501 to a regional or functional option within ABB's plus-code scheme. Their electrical effect shows up at commissioning as filter configuration and parameter defaults, not as a different enclosure, so the drive still mounts the same way and the surrounding panel layout is governed by the base frame. At 13.00 kg the unit is a one-person lift, and that mass is the load the enclosure hinge and cabinet floor carry during a swap. Plan the gland plate around the base footprint before the cable glands land.

Where this drive sits in a panel

An ACS800-01-class drive is the wall-mount workhorse of the ABB low-voltage range — used to vary speed and torque on induction and permanent-magnet motors in fans, pumps, conveyors, mixers, and extruders where direct-on-line starting would waste energy or damage the driven equipment. With the +E200 filter stage in place, the drive is aimed at installations where conducted emissions on the line side need to stay inside industrial EMC limits without a separate line filter on the gland plate. Keep motor cable length inside the drive's published limit. Long motor cables produce reflected-wave overvoltage at the motor terminals — a dV/dt or sinus filter at the drive output protects the motor winding insulation when the run is long or the cable is lower-grade than the drive expects. Mount the filter close to the drive output terminals; long pigtails between the drive and the filter defeat the filter's purpose.

Lifecycle and successor platform

ABB's published migration path moves ACS800-01 installations to the ACS880-01 platform — the same wall-mount form factor with the modern control panel and updated firmware base. Three ACS880-01 variants are on file as same-function references: ACS880-01-027A-5 at 10.41 kg, ACS880-01-034A-5 at 10.43 kg, and ACS880-01-040A-5 at 18.14 kg. The frame size step between them is what drives whether the existing backplate, gland layout, and cable terminations carry over without rework. A buyer comparing the ACS800-01-0016-5+E200+2L501 against an ACS880-01 should treat the migration as a parameter-and-firmware exercise, not a footprint swap. The control wiring, analog I/O scaling, and fieldbus option slot carry forward in principle, but the parameter set is renamed, and any application macro from the ACS800 has to be re-mapped. Plan a commissioning window, not a same-day drop-in.

Frequently asked questions

What is the closest functional second-source when sourcing ACS800-01-0016-5+E200+2L501?

Within the ABB family the ACS880-01-027A-5, ACS880-01-034A-5, and ACS880-01-040A-5 are the documented ACS880-01 wall-mount variants on file. Whether any of those is a true like-for-like substitute depends on the current rating, voltage class, and option code mapping — confirm the rating match in the RFQ before specifying a swap.

Will ACS800-01-0016-5+E200+2L501 drop into a panel built around an ACS880-01-034A-5 without rewiring?

No — the ACS800 and ACS880 share a wall-mount family look, but the parameter set, control terminal layout, and option module assignment are renamed across the generation. Treat it as a panel commissioning job: control wiring is broadly compatible, but parameter maps and fieldbus option slots need to be re-mapped.

MPN
ACS800-01-0016-5+E200+2L501