Skip to main content
ABB ACS800-U4-0210-5+E210+K451 — AC Drives (VFD)

ABB ACS800-U4-0210-5+E210+K451 AC Drive, 90.72 kgs

MPNACS800-U4-0210-5+E210+K451
End of Life

ABB ACS800-U4-0210-5+E210+K451 wall-mount AC drive, 90.72 kgs, configured with the +E210 and +K451 option codes for motor control applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ACS800-U4-0210-5+E210+K451 — Mechanical
ParameterValue
Weight90.72 kgs

Product details

The ABB ACS800-U4-0210-5+E210+K451 is a wall-mount AC drive in the ACS800-U4 frame, ordered with the +E210 and +K451 option suffixes that are part of the configured BOM line — those suffixes travel with the part number and should not be silently dropped on reorder. It sits in the Motors & Motor Controls › Drives › Motor Drives class, so the cabinet provisions to expect are standard VFD mounting, line-side fusing or breaker coordination, and motor-side cabling suited to a PWM output — not soft-starter or servo footprints.

Where it sits against same-class ABB drives

The ACS550-U1-157A-4 is the same-class peer most often cross-shopped for legacy ACS800 spares — both are wall-mount ABB industrial drives, and the listed weight is within roughly a kilogram (ACS550-U1-157A-4 at 89.81 kgs versus this unit at 90.72 kgs), so the cabinet footprint and rigging plan carry over closely; what does not carry over automatically is the parameter set, the option-suffix logic, and the control terminal layout, so a swap still needs a parameter dump and a wiring check, not just a physical lift-in. The current-generation ACS880-01-156A-5 and ACS580-01-180A-4 sit in the same current class but in substantially lighter enclosures — 55.00 kgs and 54.43 kgs respectively against this unit's 90.72 kgs — which is the kind of weight delta that signals a different mechanical frame and a re-evaluation of mounting, gland plate, and cooling clearances if modernization is on the table; treating them as like-for-like spares without checking the mechanical drawing is the kind of move that ends with the new drive sitting on the floor next to the old one.

Specifying it correctly

On the BOM line the full string ACS800-U4-0210-5+E210+K451 has to travel intact — the +E210 and +K451 suffixes are how ABB encodes the option set this drive was built and priced for, and reordering against the bare base code is a common source of a drive that arrives with the wrong firmware options enabled. For cabinet planning, the 90.72 kgs figure and the wall-mount form factor together dictate hoist access and door clearance during install; the electrical design side still needs the ABB ACS800-U4 manual for SCCR, line-side protection, and cable separation distances, none of which the order-code record carries.

Sourcing posture

Frequently asked questions

What is the closest functional second-source for ACS800-U4-0210-5+E210+K451 — is it the ACS550-U1-157A-4?

The ACS550-U1-157A-4 is the same-class ABB wall-mount drive most often cross-shopped for ACS800 spares, and the listed weights are within roughly a kilogram of each other, so the cabinet footprint carries over; what does not carry over automatically is the option-suffix logic, parameter set, and terminal layout, so a swap still needs a parameter dump and a wiring check rather than a blind lift-in.

MPN
ACS800-U4-0210-5+E210+K451