Skip to main content
ABB ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700 — AC Drives (VFD)

ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700 ABB ACS880-01

MPNACS880-01-075A-2+B056+E200+H358+L537+Q971+R700

ABB ACS880-01 series wall-mount drive, order code ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700, frame mass 6.80 kg, in the Motor Drives line.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700 — Mechanical
ParameterValue
Weight6.80 kgs

Product details

What the order code resolves to

The ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700: Mass reads 6.80 kg for this configured frame, which puts it inside the compact single-drive handling class — light enough to lift onto a backplate without a hoist, heavy enough that the panel builder should still allow for the heat-sink clearance the ACS880 series expects. Brand lineage stays ABB, so the commissioning toolchain, parameter file format and option-key decoding all follow the ACS880 standard — useful when a replacement needs to inherit a backup image rather than be re-parameterised from scratch.

Sourcing posture

Configured ACS880-01 strings like this one are specified into the BOM and quoted to order; the +056/+E200/+H358/+L537/+Q971/+R700 suffix stack is what makes each unit distinct from the bare 075A-2 base, so the order string is what should travel on the RFQ line.

Integration call-outs for a hot-strip mill

Specifying an ACS880-01 in a panel next to megawatt drives means watching common-mode noise on the encoder and feedback cable runs and keeping the control wiring well away from the power lead — the ACS880 platform is built for that environment, but the option stack on this code (+B056, +E200, +H358, +L537, +Q971, +R700) is what defines which feedback and I/O boards are present, so the panel layout has to follow the actual configured face, not the base-frame drawing. Frame mass of 6.80 kg is light enough for one person to set on the backplate, but the heat sink still wants the airflow gap the ACS880 installation guide calls for — derating kicks in when that gap is closed in, and on a mill floor where cabinet intake air already runs warm that is the curve that actually decides continuous output, not the nameplate figure.

Frequently asked questions

What is the closest functional second-source to ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700 — is it ACS880-01-07A6-5?

The closest ACS880-01 sibling in the available peer set is ACS880-01-07A6-5 at 6.35 kg, but it is a different current rating on the same wall-mount family, not a verified drop-in for the configured +B056/+E200/+H358/+L537/+Q971/+R700 option stack on the 075A-2 frame; treat it as a same-platform reference, not a confirmed swap.

Will this drive drop into a panel specified around ACS880-01-07A6-5 without rewiring?

No drop-in is asserted: ACS880-01-07A6-5 is a different current rating on the same ACS880-01 wall-mount family, and the option-code stack on this configured unit (+B056, +E200, +H358, +L537, +Q971, +R700) defines the actual I/O and feedback face; the panel layout, feedback wiring and option-board map must be rechecked against the as-configured drawing before any swap.

MPN
ACS880-01-075A-2+B056+E200+H358+L537+Q971+R700