Skip to main content
ABB S201-K3 — 1-Pole MCB (DIN Rail)

ABB S201-K3 3A K-Curve Miniature Circuit Breaker, 1-Pole, 27

MPNS201-K3

ABB S200 Series, S201-K3, 1-pole miniature circuit breaker, 3 A, Trip Curve K, 277 V AC, 6 kA interrupting capacity, DIN rail mount, UL 1077 supplemental protector.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

S201-K3 — Specifications
ParameterValue
Amps3
TypeTrip Curve K
Poles1
MountingDIN Rail
Volts AC277
Breaking capacity6 kA

Product details

What the ratings mean for fit

The S201-K3 is a 1-pole miniature circuit breaker rated 3 A continuous at 277 V AC, with a K-curve trip characteristic and 6 kA interrupting capacity. It's a UL 1077 supplemental protector — meaning it's listed for branch-circuit back-up protection inside equipment, not as a service-entrance main breaker. The K-curve (10–14x In magnetic trip) is the key spec: it's designed to ride through the high inrush of motor starters, transformers, and solenoid valves without nuisance tripping, while still clearing a hard short. At 3 A, this is sized for a small motor or control transformer secondary, not a feeder. The 6 kA SCCR at 277 V tells you it can safely interrupt a fault up to that level without welding contacts or cascading upstream — adequate for most panelboards behind a 10 kA main, but verify coordination if the available fault current at the panel exceeds that.

Where it lands in the panel

Snaps onto standard DIN rail (35 mm) in any enclosure. Single-pole width means it takes one module slot — 17.5 mm — so it fits tight layouts. The S200 series shares a common busbar and accessory footprint across the line, so you can mix K-curve and other curves on the same rail without extra adapters. Terminal torque is typically 2–2.5 Nm; strip length around 10 mm for the cage clamp.

Frequently asked questions

What is the S201-K3's interrupting rating?

6 kA at 277 V AC, per UL 1077. That's the maximum fault current it can safely clear without failing.

What does Trip Curve K mean on this breaker?

K-curve means the magnetic trip operates at 10 to 14 times the rated current (30–42 A for the 3 A version). It's chosen for loads with high inrush — motors, transformers, solenoids — so it doesn't trip on startup but still clears a short fast.

Where can I buy the S201-K3?

We source it to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send the RFQ and we'll quote the line.

What compliance documentation does ABB provide for the S201-K3?

The part carries UL 1077 and CSA 22.2 approvals. Standard documentation includes the UL listing mark on the nameplate and a CSA certification. RoHS and REACH compliance is typical for the S200 series, but confirm the specific declaration with the order.

MPN