Skip to main content
ABB S202M-C40 — 2-Pole MCB (DIN Rail)

ABB S202M-C40 S200M MCB, 40 A, Curve C, 2-Pole

MPNS202M-C40

ABB S200M series, S202M-C40, 2-pole miniature circuit breaker, 40 A, Trip Curve C, DIN rail mount, 277 VAC / 125 VDC, 6 kA interrupting rating AC.

$26.67Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

S202M-C40 — Specifications
ParameterValue
Amps40
TypeTrip Curve C
Poles2
MountingDIN Rail
Volts AC277
Volts DC125
Breaking capacity6 kA
Interrupt rating DC10 kA

Product details

On DC circuits it handles 10 kA at 125 VDC, which covers most industrial control bus and battery backup feeds.

The S202M-C40 is the 40 A, 2-pole member of the S200M series. Its closest siblings are the single-pole S201M-C3 (3 A, same curve C) and the 3-pole S203-C8 (8 A, 10 kA interrupting AC). The key difference for a buyer: if your panel was wired around the S201M-C3, the S202M-C40 will not drop in without rewiring the neutral and load connections — same DIN-rail footprint, but the pole count and amp rating are different. The S203-C8 offers a higher interrupting capacity (10 kA vs 6 kA) at 277 VAC, which matters if the available fault current at the panel exceeds 6 kA.

Frequently asked questions

Where can I buy S202M-C40 and how do I get a price?

The S202M-C40 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

When sourcing S202M-C40, what's the closest functional second-source — S201M-C3?

The S201M-C3 is not a functional second-source for the S202M-C40 — it is a 3 A single-pole breaker, while the S202M-C40 is a 40 A 2-pole breaker. Both share the S200M DIN-rail footprint and Trip Curve C, but the amp rating and pole count are different. For a 40 A 2-pole requirement, the S202M-C40 is the correct order code.

What is S202M-C40's listed amps (40) on this component line?

The S202M-C40 is rated 40 A continuous current.

What is S202M-C40's listed type (Trip Curve C) on this component line?

The S202M-C40 uses Trip Curve C, which trips at 5–10 times rated current — suited for general-purpose loads with moderate inrush.

Will S202M-C40 drop into a panel that was specified around S201M-C3 without rewiring?

No — the S202M-C40 is a 2-pole breaker, while the S201M-C3 is single-pole. Both mount on the same DIN rail, but the wiring (line, load, and neutral connections) differs. You would need to rewire the circuit to match the 2-pole configuration.

What compliance documentation does this brand provide for S202M-C40 (RoHS, REACH, UL, IEC)?

The S202M-C40 is an ABB S200M series MCB. ABB typically provides RoHS, REACH, and IEC/EN 60898-1 compliance documentation for this series. For specific declarations (CE, UKCA, UL listing), request the manufacturer's declaration of conformity with your RFQ.

MPN