ABB S202MUC-C20 — 2-Pole MCB (DIN Rail)

ABB S202MUC-C20 S200MUC MCB 2P C 20A, 6kA/10kA

MPNS202MUC-C20

ABB S200MUC series, S202MUC-C20 miniature circuit breaker, 2-pole, 20 A, Trip Curve C, 277 VAC / 500 VDC, 6 kA AC / 10 kA DC interrupting capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

S202MUC-C20 — Specifications
ParameterValue
Amps20
TypeTrip Curve C
Poles2
MountingDIN Rail
Volts AC277
Volts DC500
Breaking capacity6 kA
Interrupt rating DC10 kA

Product details

It interrupts faults at 6 kA on AC circuits up to 277 V and 10 kA on DC circuits up to 500 V — the DC rating is notably higher than many comparable MCBs, making it a fit for DC bus or battery-string protection where the fault current can be stiffer.

Curve C and interrupting capacity

Trip Curve C means the magnetic trip operates at 5 to 10 times rated current (100–200 A for this 20 A unit). The 6 kA AC interrupting rating at 277 V is standard for branch-circuit protection in a distribution board; the 10 kA DC rating at 500 V is less common and tells you the arc-quenching chamber is designed for DC commutation, not just AC zero-crossing.

The S200MUC family shares the same footprint as the broader S200 series, so it swaps into an existing ABB distribution board or sub-panel without re-drilling the backplate. Spring-loaded terminal clamps accept 0.5–25 mm² conductors; torque to 2.5 Nm.

Frequently asked questions

What is the S202MUC-C20's interrupting capacity on AC and DC?

It interrupts 6 kA on AC circuits up to 277 V and 10 kA on DC circuits up to 500 V. The DC rating is higher than the AC rating, which is unusual and suits DC bus protection.

Will the S202MUC-C20 drop into a panel specified around the S202M-B10?

Yes — both are 2-pole S200MUC family MCBs on the same DIN-rail footprint. The difference is the trip curve (C vs B) and the amp rating (20 A vs 10 A). The S202MUC-C20 will physically fit and wire in identically, but the trip curve and amp rating must match the circuit's design.

Where can I buy the S202MUC-C20 and how is it quoted?

The S202MUC-C20 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.