Skip to main content
ABB S202MUC-K40 — 2-Pole MCB (DIN Rail)

ABB S202MUC-K40 MCB 2P K 40 A, 500 VDC

MPNS202MUC-K40

ABB S200MUC series, 2-pole K-curve MCB, 40 A, 277 VAC / 500 VDC, 6 kA / 10 kA interrupting capacity, DIN-rail mount.

$269.79Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

S202MUC-K40 — Specifications
ParameterValue
Amps40
TypeTrip Curve K
Poles2
MountingDIN Rail
Volts AC277
Volts DC500
Breaking capacity6 kA
Interrupt rating DC10 kA

Product details

It handles 277 VAC at 6 kA interrupting capacity and 500 VDC at 10 kA — the DC rating is notably high for a compact MCB, making it a fit for DC distribution panels, UPS outputs, or solar combiner boxes where the string voltage stays under 500 VDC. The K-curve trips between 10× and 14× rated current, designed for inductive loads like motor starters and transformers that draw a high inrush without nuisance tripping on the branch circuit.

The K-curve means magnetic trip occurs at 10–14× In (400–560 A instantaneous), so it rides through the inrush of a 15–20 kVA transformer or a bank of DC power supplies without opening. The 500 VDC rating with 10 kA interrupting capacity is the standout: most 2-pole MCBs in this footprint top out at 125 VDC or 250 VDC, so if you are protecting a 400 VDC bus in a telecom or industrial DC system, this part holds the arc without welding contacts.

Two-pole width is 36 mm (2 modules of 18 mm each). The S200MUC family uses tunnel terminals accepting 1–25 mm² conductor — no special busbar or adapter needed for the 40 A feed. Wire strip length 12 mm, torque to 2.5 Nm. For DC circuits, observe polarity marking on the terminal; the internal arc chamber is polarized for DC interruption.

Frequently asked questions

Where can I buy S202MUC-K40 and how do I get a price?

The S202MUC-K40 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is S202MUC-K40's listed amps and trip curve?

The S202MUC-K40 is rated 40 A with a K-curve trip characteristic (magnetic trip at 10–14× In).

Will S202MUC-K40 drop into a panel specified for S202M-C63 without rewiring?

Both mount on 35 mm DIN rail and share the same 2-pole, 36 mm footprint. The S202M-C63 is a 63 A C-curve breaker with a lower DC voltage rating (125 VDC vs 500 VDC). If the panel was wired for 63 A, the 40 A S202MUC-K40 cannot simply replace it without checking the load current and coordination — the K-curve also trips at a higher multiple of rated current, so the magnetic trip threshold is different.

What compliance documentation does ABB provide for S202MUC-K40?

ABB provides a declaration of conformity to IEC/EN 60898-1 and IEC/EN 60947-2. The S200MUC series carries CE and UKCA marking. RoHS and REACH compliance declarations are available on request through the supply chain.

MPN