ABB S202P-K40 — 2-Pole MCB (DIN Rail)

ABB S202P-K40 MCB 2P K 40A 480Y/277, 10 kA

MPNS202P-K40

ABB S202P-K40, 2-pole miniature circuit breaker, 40 A, Trip Curve K, 277 VAC, 10 kA interrupting rating, DIN rail mount.

$39.37Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

S202P-K40 — Specifications
ParameterValue
Amps40
TypeTrip Curve K
Poles2
MountingDIN Rail
Volts AC277
Breaking capacity10 kA

Product details

The ABB S202P-K40 is a 2-pole miniature circuit breaker rated 40 A with Trip Curve K, designed for 277 VAC (480Y/277 V systems) and a 10 kA interrupting rating. The K curve provides magnetic trip between 8x and 12x In, making it suited for motor branch circuits and transformer primary protection where high inrush currents are expected — the breaker holds through the start surge but clears a hard fault fast.

40 A continuous rating on a 2-pole breaker means it handles up to 40 A per pole in a 277 V line-to-neutral or 480 V line-to-line circuit. Trip Curve K is the deciding factor for motor loads: magnetic trip starts at 8x rated current (320 A) and is guaranteed by 12x (480 A). This means a 40 A motor drawing 6x locked-rotor current (240 A) during start will not nuisance-trip, but a dead short exceeding 480 A clears in under 10 ms. For resistive or general-purpose loads, Curve C or B would trip faster — K is specifically for inductive inrush.

DIN rail mount (per EN 60715) clips into any standard 35 mm rail in a distribution board or control panel. The 2-pole width is 36 mm (2 modules of 18 mm). For a panel OEM, the fill factor is one slot per pole; derating per IEC 60898 applies when ambient exceeds 30 °C or when multiple breakers are ganged without spacing.

Frequently asked questions

What is the closest functional second-source to S202P-K40?

The S202P-K32 is the same 2-pole K-curve breaker at 32 A instead of 40 A. It shares the same 277 VAC rating, 10 kA interrupting capacity, and DIN rail footprint. If the panel was specified around the S202P-K32, the S202P-K40 drops in without rewiring — same terminals, same busbar pitch, same trip curve shape — just a higher continuous rating. Verify the load current before swapping up.

Will S202P-K40 drop into a panel that was specified around S202P-K32 without rewiring?

Yes. Both are 2-pole K-curve breakers on the same DIN rail footprint with identical terminal layout and busbar pitch. The only difference is the continuous rating: 40 A vs 32 A. No wiring changes needed — just confirm the downstream load is within 40 A.

Where can I buy S202P-K40 and get current pricing?

The S202P-K40 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.